Download Print this page

Tate poweraire quad Installation Manual

Quad-fan assist

Advertisement

Quick Links

Installation Guide: PowerAire® Quad
r2.0-7/8/14
Quad- S: 16943, 17351 Quad- M: 16886, 16633 Quad- C: 17347, 17348
INSTALLATION GUIDE FOR POWERAIRE® QUAD
QUAD-FAN ASSIST
7510 Montevideo Road
© 2012 Tate Access Floors, Inc.
Jessup, MD 20794
Tel (410)799-4200
1 of 15

Advertisement

loading

Summary of Contents for Tate poweraire quad

  • Page 1 Installation Guide: PowerAire® Quad r2.0-7/8/14 Quad- S: 16943, 17351 Quad- M: 16886, 16633 Quad- C: 17347, 17348 INSTALLATION GUIDE FOR POWERAIRE® QUAD QUAD-FAN ASSIST 7510 Montevideo Road © 2012 Tate Access Floors, Inc. Jessup, MD 20794 Tel (410)799-4200 1 of 15...
  • Page 2: Method Of Operation

    METHOD OF OPERATION Tate’s PowerAire® Quad Fan product is designed to work in conjunction with the DirectAire® Airflow Panels, to meet high airflow requirements and accurate air flow deliver to the rack face. The PowerAire® Quad Fan is designed to alleviate airflow issues in areas where little to no static pressure exists due to Underfloor restrictions, or insufficient floor heights.
  • Page 3: Installation Instructions

    E. 4 x Tool Less Roll Formed Stringer Hangers F. 1 x PowerAire® power cord Not Pictured: The PowerAire® Quad is designed for optimum use with Tate’s DirectAire® airflow panel ordered separately; other airflow panels may reduce the performance of the PowerAire® Quad.
  • Page 4 Figure 3 - Insert hanger into roll form opening and catch the top angle inside the stringer Figure 4 - Release hanger and allow it to return perpendicular to the floor 7510 Montevideo Road © 2012 Tate Access Floors, Inc. Jessup, MD 20794 Tel (410)799-4200...
  • Page 5 Once this side is also resting in the hanger support, manipulated the unit so that each hanger on the alternate sides are also secure the unit into place. 7510 Montevideo Road © 2012 Tate Access Floors, Inc. Jessup, MD 20794 Tel (410)799-4200...
  • Page 6 If a new hole is required, ensure that the hole is sealed after the temperature probes are completely routed, and that the holes edges are appropriately grommeted to decrease the risk of cable damage. 7510 Montevideo Road © 2012 Tate Access Floors, Inc. Jessup, MD 20794 Tel (410)799-4200 6 of 15...
  • Page 7 IT operation. See figure 11 through 13 for routing examples. 7510 Montevideo Road © 2012 Tate Access Floors, Inc. Jessup, MD 20794 Tel (410)799-4200 7 of 15...
  • Page 8 Figure 12,13 - Temperature Sensor installation Securing Sensor Tree to Rack with Sufficient Slack for Door Operation PowerAire Quad- S or M units should skip step 8 8. For installation of Quad Fan C units a control signal of 0-10VDC should be provided via an alternate means than the provided equipment.
  • Page 9 Figure 14- Connecting power to the unit Figure 15 - Plugging the power cord into the unit Figure 16 – Location of Power Switch 7510 Montevideo Road © 2012 Tate Access Floors, Inc. Jessup, MD 20794 Tel (410)799-4200 9 of 15...
  • Page 10 E. Pressing the SEL button again will return the user to main screen which displays the current peak temperature value recorded from the temperature sensor tree. Figure 18 shows this procedure. Figure 17 - Scrolling Through Temperature Values 7510 Montevideo Road © 2012 Tate Access Floors, Inc. Jessup, MD 20794 Tel (410)799-4200 10 of 15...
  • Page 11 Figure 18 - Programming Set point for Control For Quad-Fan M and C units, Skip step 13. 7510 Montevideo Road © 2012 Tate Access Floors, Inc. Jessup, MD 20794 Tel (410)799-4200 11 of 15...
  • Page 12 Press set once more and the new set point value will be stored. Figure 19 - Scrolling Through Temperature Value ® Figure 20 - Installation of DirectAire Panel Figure 21 - Typical Operation 7510 Montevideo Road © 2012 Tate Access Floors, Inc. Jessup, MD 20794 Tel (410)799-4200 12 of 15...
  • Page 13 PowerAire unit. See figure 22 below Figure 22 - WARNING - Ensure power is switched off before accessing unit 7510 Montevideo Road © 2012 Tate Access Floors, Inc. Jessup, MD 20794 Tel (410)799-4200 13 of 15...
  • Page 14 Quad –S for use within the interior portion of an aisle. ® ® Figure 23 – PowerAire Quad – M and S installation wiring diagram 7510 Montevideo Road © 2012 Tate Access Floors, Inc. Jessup, MD 20794 Tel (410)799-4200 14 of 15...
  • Page 15 Rack Rack PowerAire PowerAire Quad - C Quad - C w/DirectAire w/DirectAire ® Figure 24 – PowerAire Quad – C installation wiring diagram 7510 Montevideo Road © 2012 Tate Access Floors, Inc. Jessup, MD 20794 Tel (410)799-4200 15 of 15...