Mitsubishi Electric MT819 Operation Manual page 20

52" lcd display monitor
Table of Contents

Advertisement

Controlling the Monitor with a PC (RS-232C)
PIP/PbyP menu
Function
PIP MODES
PIP SIZE
PIP POS
THE LONGEST
DIRECTION
THE SHORTEST
DIRECTION
PIP POS LD+SD BATCH
PIP BLEND
PIP SOURCE
SOUND CHANGE
MAIN POS (Main screen)
PbyP2 POS (Sub screen)
AUTO OFF
Initialization/Functional Restriction Setting (FUNCTION) menu
Function
ALL RESET
ADJUSTMENT LOCK
OSD DISPLAY
LED
TEMPERATURE ALERT
STATUS ALERT
Others
Function
SCREEN SIZE (PC)
SCREEN SIZE (AV)
VOLUME
MUTE
INFORMATION
MODEL
SERIAL NO
BRIGHT
TEMPERATURE SENSOR
TEMPERATURE ACQUISITION
CAUSE OF LAST STANDBY MODE
20
E
Command
Direction
Parameter
MWIN
WR
0-3
MPSZ
WR
1-12
MHPS
W
0-100
R
MVPS
W
0-100
R
MPOS
W
0-100,0-100
R
MWBL
WR
0-15
MWIP
WR
1
2
3
4
6
7
8
9
10
MWAD
WR
1-2
MWPP
WR
0-1
MW2P
WR
0-2
MOFF
WR
0-1
Command
Direction
Parameter
RSET
W
0-1
ALCK
WR
0-2
LOSD
WR
0-1
OFLD
WR
0-1
TALT
WR
0-2
SALT
WR
0-2
Command
Direction
Parameter
WIDE
WR
1-5
WIDE
WR
1-5
VOLM
WR
0-31
MUTE
WR
0-1
INF1
R
SRNO
R
VLMP
WR
0-31
DSTA
R
ERRT
R
STCA
W
0
R
Reply
Control/Response contents
0-3 0: OFF, 1: PIP, 2: PbyP, 3: PbyP2
1-12
0-100
0-100
Specify the position in MPOSxxxyyy format.
(xxx: Longer side, yyy: Shorter side position)
0-100,0-100 Returns a response in (xxx,yyy) format.
(xxx: Longer side, yyy: Shorter side position)
0-15
1 PC1 DVI-D
2 PC3 D-SUB
3 AV3 COMPONENT
4 AV5 VIDEO
6 PC4 RGB
7 AV1 DVI-D
8 AV4 S-VIDEO
9 AV2 HDMI
10 PC2 HDMI
1-2 1: MAIN, 2: SUB
0-1 0: POS1, 1: POS2
0-2 0: POS1, 1: POS2, 2: POS3
0-1 0: MANUAL, 1: AUTO
Reply
Control/Response contents
0: ALL RESET 1, 1: ALL RESET 2
0-2 0: OFF
0-1 0: ON, 1: OFF
0-1 0: ON, 1: OFF
0-2 0: OFF, 1: OSD & LED, 2: LED
0-2 0: OFF, 1: OSD & LED, 2: LED
Reply
Control/Response contents
1-5 1: WIDE, 2: NORMAL, 3: Dot by Dot, 4: ZOOM1, 5: ZOOM2
1-5 1: WIDE, 2: ZOOM1, 3: ZOOM2, 4: NORMAL, 5: Dot by Dot
0-31
0-1 0: OFF, 1: ON
Value
Value
0-31 Brightness
0 Internal temperature normal
1 Internal temperature abnormal (Standby mode)
2 Internal temperature abnormal (Temperature is normal now, but it was
abnormal during operation.)
3 Internal temperature abnormal (Brightness of the backlight decreases.)
4 Temperature sensor abnormal
Value Temperature at temperature sensors 1 through 3 are returned in the
following forms:
[Sensor 1], [Sensor 2], [Sensor 3]
Indicates a temperature sensor abnormality when "126" is returned.
Initialization
0 No detectable error has occurred
1 Standby mode by POWER button
2 Main power "OFF" by the main power switch
3 Standby mode by RS-232C or LAN
4 Waiting mode by No Signal (Incl: VESA DPMS/DMPM)
6 Standby mode by abnormal temperature
8 Standby mode by SCHEDULE setting
*
B
B
B
B
B
B
B
B
B
B
B
B
B
B
*
-
B
B
B
B
B
*
B
B
B
-
A
B
A
A
A