U-Line ADA24R User Manual page 49

Ada series 24" solid door refrigerator
Hide thumbs Also See for ADA24R:
Table of Contents

Advertisement

USER GUIDE
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
ELECTRONIC CONTROL DESCRIPTIONS QUICK
GUIDE
Except as noted, these functions are available on all
models.
ON/OFF
1.
The ON/OFF mode allows the unit to be turned on and
off via the keypad. Push/release power key to toggle
ON/OFF. Internal lights will go off with power.
TOGGLE LIGHT
2.
On units with glass doors, touching the LIGHT key will
turn on the cabinet light for 3 hours at a time.
Touching the key again will turn the light off. Using the
cabinet light for more than 3 hours may be detrimental
to the cabinet temperature and product. Only available
on BEV, WC models.
NOTICE
This does not apply to ADA24R glass door units.
The light and display are always off when the
glass door is closed.
ADJUSTING THE SET POINT
3.
To adjust the set point press and release either the
WARMER or COLDER key. This will start the set point
flashing. While in this mode you can adjsut the set
point warmer or colder until the desired temperature is
reached. When adjustment is complete stop touching
the display and the set point will be saved in
approximately five seconds.
VIEWING ACTUAL TEMPERATURE
4.
In viewing temperature in these modes any offsets are
taken into account. This means that if you place a
thermistor in a known temperature, let's say ice water,
it may not read the 32°F that you would assume. If the
control offset was preset at -3°F while you placed the
thermistor in an icebath, the actual thermistor reading
when viewing actual temperature would read 35°F. In
the unit this would cause the cabinet to push itself 3°
cooler. To view pure thermistor readings you must go
into the service menu and choose the correct option.
To view the thermistor temperature, push and release
the up and down keys. The display will show the
corrected refrigerator temperature.
CHANGING FROM FAHRENHEIT TO
5.
CELSIUS
To change the displayed temperature from °F to °C,
push and hold the up and down arrows for 5 seconds.
Repeat to change back.
SHOWROOM MODE
6.
This mode is designed to show units in a display
environment. When in this mode the only functions will
be the control and cabinet lights. The compressor,
fans, etc. will not operate. To enter this mode hold the
light key and the power key for 5 seconds. The display
will flash once and beep and the degree symbol will
begin to flash. When the degree symbol is flashing the
unit will allow the use of the control for
demonstrations. The unit can be left in this mode
indefinitely. To exit this mode, interrupt power to the
unit.
SERVICE MODE
7.
This mode has 28 different options available for service
diagnostics. To enter the mode hold the hidden key for
10 seconds. The display will show "0." When in this
mode use the up and down arrows to select the desired
option. The LIGHT key is the ENTER key and will enter
a function. If changing a setting, you must press the
LIGHT key again to retain the changed setting. To exit
the service mode scroll to option "0" and press the
LIGHT key. After five minutes of not touching any keys
the mode will also exit automatically.