Installation Instructions
If you have a heat pump without aux heat, the Daikin model will
D.
require 5 wires: R (24Vac), C (24Vac), W1/O/B (Reversing Valve), Y (1
Stage Compressor), and G (Fan).
If you are short 1 wire, there are at least 3 options available to connect
the Daikin thermostat:
1. Use the available wires as instructed in the"Making 4 Wires
Work When 5 Wires Are Required" section on page 56 and note
that the fan will only operate with a Heating or Cooling demand.
2. Pull new thermostat wire from the HVAC equipment to the
thermostat so that there are at least 5 wires available.
3. Purchase and install a Daikin Add-A-Wire accessory.
E.
If you have a heat pump with aux heat, the Daikin model will require 6
wires: R (24Vac), C (24Vac), W1/O/B (Reversing Valve),
Y (1
Stage Compressor), W2 (Aux Heat), and G (Fan).
st
If you are short 1 wire, there are at least 3 options available to connect
the Daikin thermostat:
1. Use the available wires as instructed in the"Making 5 Wires
Work When 6 Wires Are Required" section on page 57 and note
that the fan will only operate with a Heating or Cooling demand.
2. Pull new thermostat wire from the HVAC equipment to the
thermostat so that there are at least 6 wires available.
3. Purchase and install a Daikin Add-A-Wire accessory.