HDG Compact 25 Operation Manual page 101

Hide thumbs Also See for Compact 25:
Table of Contents

Advertisement

No.
Display
1-25
Power supply
3x400V/N
3x230V
1x230V
1x230V R
1-26
General
Mixing valve runtime
(
2.0)
1-27
Phase order error
Off
On
2 - B
OILER
No.
Display
2-00
Set temp. via
HC ctrl/acc.
Outdoor
External
Outdoor/external
2-01
Terminal 38-39
Demand
Blockage
2-02
Boiler
Set temperature
( 60)
2-03
Boiler
Set temperature
( 80)
2-04
Boiler
Set temperature
( 5)
Description
Selection of the supply voltage.
Setting the minimum running time.
Minimum
2.0 s
Messages about errors in the phase order can be
deactivated.
Table 6/3 - System level / 1 - General
Warning!
Do not set the maximum boiler temperature above 80 °C.
Description
with HDG Hydronic system connected
with variable boiler temp. and external controller
enable via external control and constant boiler temp.
with external demand and variable boiler temperature
Selecting the functions assigned to terminals 38 and 39.
Minimum target temperature to be preset for the boiler.
(50 - 65 °C)
Minimum
60°
Specifies the maximum boiler target temperature.
Maximum
(50 - 80 °C)
80°
To achieve the required supply temperature for the loads,
the boiler temperature is increased.
override
(0 - 10 °C)
Table 6/4 - System level / 2 - Boiler
6 Using the heating system – Structure of the menus
Supply voltage
Return mix. valve
Phase order
Defining the preset boiler temperature
Terminal 38 - 39
Minimum preset boiler temperature
Maximum preset boiler temperature
Preset boiler temperature increased
101