Solution Ultima 862 Operators Manual Introduction Congratulations on selecting the Solution Ultima 862 control panel to protect you and your property. So that you can obtain the most from your unit, we suggest that you take the time to read through this manual and familiarise yourself with the numerous outstanding operating features of this system.
Solution Ultima 862 Operators Manual Codepad Indicators Figure 1: CP5 Eight Zone Figure 2: CP5 Eight Zone LED Codepad LCD Codepad The codepad is the communications interface between you and your alarm system. The codepad allows you to issue commands and offers both visual and audible indications that guide you through the general operation.
Solution Ultima 862 Operators Manual STAY Indicator The STAY indicator is used to display that the system is armed in STAY Mode 1 or STAY Mode 2. The STAY indicator will also flash in unison with the AWAY indicator when programming various options throughout the operator’s manual.
Solution Ultima 862 Operators Manual FAULT Indicator The FAULT indicator is used to display that the system has detected a system fault. Refer to Fault Analysis Mode on page 17 for additional information on system faults. Every time a new system fault has been detected (eg: FAULT indicator flashing), the codepad will begin to beep once every minute.
Solution Ultima 862 Operators Manual Arming The System There are several different ways to arm the system depending on whether you are leaving the premises and require all active zones to be in a ready state for an intruder, or, if you are remaining in the premises and only require part of the system to be in a ready state for an intruder.
Solution Ultima 862 Operators Manual Arming In STAY Mode 1 STAY Mode 1 is only used when the perimeter and unused areas of the premises need to be armed to detect any would be intruder from entering the premises and at the same time, allowing you to move freely within an area that has been automatically isolated.
Solution Ultima 862 Operators Manual Arming In STAY Mode 2 STAY Mode 2 is only used when the perimeter and unused areas of the premises need to be armed to detect any would be intruder from entering the premises and at the same time, allowing you to move freely within an area that has been automatically isolated.
Solution Ultima 862 Operators Manual Disarming The System When you enter the premises after the system has been armed in AWAY Mode, or if you have armed the system in STAY Mode 1 or STAY Mode 2, you will need to disarm the system to disable detection devices that will activate an alarm.
Solution Ultima 862 Operators Manual Deleting User Codes/Radio User Codes Only the Master Code holder can delete other system user codes. How To Delete A User Code Enter your Master Code followed by 1 and the # button (eg: 2580 + 1#).
Solution Ultima 862 Operators Manual Codepad Duress Alarm A codepad duress alarm is used as a silent hold-up alarm. This will only occur when the number 9 is added to the end of any valid user code that us being used to disarm the system (eg: 2580 + 9#).
Solution Ultima 862 Operators Manual Isolating Zones Isolating zones allow you to manually disable one or more zones before arming the system. Once a zone has been isolated, access is allowed into that zone during the armed state without activating an alarm.
Solution Ultima 862 Operators Manual Code To Isolate The method of code to isolate restricts only those user codes that have the priority level “Code To Isolate” set to be able to isolate zones. Therefore, if any user code has this priority level set, the method of standard isolating will not function.
Page 18
Solution Ultima 862 Operators Manual Zone Fault Hold Down Zone Fault Indicator Description Button Indicator Condition System Fault Low Battery Date & Time RF Receiver Fail Horn Speaker Telephone Line Fail E2 Fault Fuse Fail Zones 1 - 8 RF Low Battery...
Solution Ultima 862 Operators Manual Fault Descriptions System Fault A system fault will only display when any of the following faults occur. After entering fault analysis mode, holding down button 1 will determine which of the following faults have occurred.
Solution Ultima 862 Operators Manual Tamper Fail This fault will occur when any zone has become open circuit. By holding down button 3 until two beeps are heard in fault analysis mode will display which zone has reported the tamper fail fault.
Solution Ultima 862 Operators Manual Telco Arm/Disarm Sequence This feature allows you to program the Telco Arm Sequence (Option 1) and Telco Disarm Sequence (Option 2). Option 1 – Telco Arm Sequence This allows you to program the Call Forward – Immediate On sequence or Call Forward –...
Solution Ultima 862 Operators Manual How To Program The Telco Disarm Sequence Enter your Master Code followed by 3 and the # button (eg: 2580 + 3#). Three beeps will be heard and the STAY and AWAY indicators will flash.
Solution Ultima 862 Operators Manual Testing There are various functions that allow you to test that your system is operating correctly. Horn Speaker Test Hold down button 1 until two beeps are heard. The horn speaker will sound for two seconds.
Solution Ultima 862 Operators Manual Day Alarm Day alarm allows a combination of zones to be monitored during the disarmed state by beeping the codepad buzzer. Only your installer can program zones 1 – 4 to operate for day alarm.
Solution Ultima 862 Operators Manual Domestic Dialling Domestic dialling can be used to call your mobile phone or a relative/friend in the event that your control panel has activated an alarm. Up to three different telephone numbers may be programmed for the control panel to call when alarm occurs. Only your installer can set the system to report in the domestic format, however, the Master Code holder may change the domestic telephone numbers at any time.
Solution Ultima 862 Operators Manual Programming Domestic Telephone Numbers If your system has been set-up for domestic dialling, this function allows any Master Code holder to program telephone numbers that the control panel will call in the event of an alarm.
Solution Ultima 862 Operators Manual Basic Pager Reporting This feature is only applicable if your system is reporting to a pocket pager. Basic pager reporting requires some interpretation of the numbers that appear of the display. However, it is possible to differentiate between 1000 different systems when a number of control panels are reporting to the one pocket pager.
Page 28
Solution Ultima 862 Operators Manual Figure 4: Basic Pager Display The example above shows that the transmission has come from the control panel that has an ID number of 678 and that zone 2 is in alarm. The example also displays that zone 3 has been manually isolated and the system is armed.
Solution Ultima 862 Operators Manual Glossary Of Terms Term Description Alarm Condition Is when your alarm system is armed and one of the detection devices have been violated. A 24-hour zone (eg: smoke detector) can activate an alarm condition when your system is armed or disarmed.
Page 30
Solution Ultima 862 Operators Manual Term Description Isolating Allows you to manually disable (isolate) one or more zones before arming the system. Master Code Is a numerical code used for arming and disarming the system as well as allowing access to functions such as adding and deleting user codes etc.
Year 2000 Compliance This notice is to confirm that all Solution Ultima 862 control panels are not susceptible to, or can be corrupted by the “Year 2000 Millennium Bug”. To date, all Solution products that incorporate time keeping functions employ a rotating 100- year calendar.
The Austel permit that has been issued for this product is subject to the following conditions: • The Solution Ultima 862 control panel may only be powered by an EDM TF008 plug pack (Approval Number Q92128). New Zealand Telepermit Notes •...
Solution Ultima 862 Operators Manual Installation Notes Installation Company Technicians Name Technicians Telephone Number Installation Date Warranty Expires Panel Software Version Service Notes Electronics Design and Manufacturing Pty Limited ISSUE100.DOC...
Page 34
Solution Ultima 862 Operators Manual Zone Descriptions This allows you to describe each zone and tick which zones have been programmed to be automatically isolated in STAY Mode 1 or have been programmed for day alarm operation. Isolated In STAY...
Solution Ultima 862 Operators Manual Entry / Exit Times Entry Timer 1 Exit Time Entry Timer 2 Entry Guard Time Arming Options Single Button Arming Forced Arming Single Button Disarming Remote Arming Via Telephone Automatic Arming Time AM/PM Automatic Disarming Time...
Page 36
Solution Ultima 862 Operators Manual 9 Digit RF User Code ID Numbers Radio User Code 9 ID Number Radio User Code 10 ID Number (Place RF Radio Keyfob ID Sticker Here) Radio User Code 10 ID Number Radio User Code 14 ID Number...