Outdoor heater
Table of Contents

Advertisement

OPERATION
CAUTION : AVOID INHALING FUMES EMITTED FROM THE HEATER'S FIRST USE. SMOKE AND
ODOR FROM THE BURNING OF OILS USED IN MANUFACTURING WILL APPEAR. BOTH
SMOKE AND ODOR WILL DISSIPATE AFTER APPROXIMATELY 30 MINUTES. THE HEATER
SHOULD NOT PRODUCE THICK BLACK SMOKE.
NOTE:
The burner may be noisy when initially turned on. To eliminate
excessive noise from the burner, turn the Control Knob to the "LOW"
position. Then, turn the knob to the level of heater desired.
When heater is ON:
Emitter grid will become bright red due to intense heat. The color
is more visible at night.
These flames should not or produce thick black smoke, indicating an
obstruction of airflow through the burners.
Operation pressure checked:
If the flame is very small, this is because the supply pressure is not
enough. Please refill gas cylinder.
Re-light:
1) Turn the control knob to "OFF" position.
2) Wait five (5) minutes before attempting to relight pilot.
3) Repeat steps beginning with step 2 of the lighting instruction
above.
Shut down instructions:
1) Push in and turn control knob clockwise to "OFF" position.
2) Turn LP cylinder gas valve clockwise to "OFF" position when
heater is not in use.
Note: After use, some discoloration of the emitter screen is normal.
The Event of Gas Leakage:
1) Turn the control knob to "OFF" position.
2) Turn LP cylinder valve to "OFF" position.
3) Wait 5 minutes to allow gas to dissipate.
4) If odor continues, immediately call gas supplier.
WARNING : Heater will be hot after use.
Handle with extreme care.
13

Hide quick links:

Advertisement

Table of Contents
loading