8.
If you smell gas following the five minute waiting pe-
riod in step 7, immediately follow the instructions on
the cover of this manual. If you do not smell gas after
five minutes, move the furnace's gas valve ON/OFF
switch to the ON position.
9.
Replace the burner compartment door.
10. Open the external manual gas shut-off valve.
11. Turn on the electrical power to the furnace.
12. Adjust the thermostat to a setting above room tem-
perature.
13. After the burners are lit, set the thermostat to desired
temperature.
Gas Valve On/Off
Selector Switch
Honeywell Model VR8215 (Single-Stage)
Gas Valve On/Off
Selector Switch
Honeywell Model VR9205 (Two-Stage)
White-Rodgers Model 36G22/36J22 (Single-Stage)
White-Rodgers Model 36G54/36J54(Two-Stage)
F
S
D
URNACE
HUT
OWN
To shut down your furnace, follow the steps listed below.
1. Set the thermostat to the lowest setting.
2. Integrated control closes gas valve extinguishing flame.
3. Induced draft blower is de-energized following a 15 sec-
ond delay. The circulator blower is de-energized fol-
lowing a 90, 120, 150, or 180 second delay period.
4. Remove the burner compartment door.
5. Move the furnace's gas valve ON/OFF switch to the OFF
position.
6. Close the external manual gas shut-off valve.
7. Replace the burner compartment door.
L
R
OCKOUT
ESET
Furnace lockout is characterized by a non-functioning fur-
nace (circulator blower may be running continuously) pro-
viding a diagnostic LED code. Lockout results when a fur-
nace control detects abnormal conditions. If the furnace
is in "lockout", it may be reset by any of the following
methods:
1. One hour automatic reset. Control will automatically
reset itself and attempt to resume normal operations
following a one hour lockout period.
2. Power interruption. Interrupt 115 volt power to the fur-
nace for greater than 20 seconds.
3. Thermostat cycle. Interrupt thermostat signal to the
furnace for between 0 and 20 seconds.
If the condition which originally caused the lockout still
exists, the control will return to lockout. If your furnace
frequently locks out, a problem exists which must be cor-
rected. Contact a qualified servicer.
R
M
OUTINE
AINTENANCE
Maintenance is to be performed by a qualified service tech-
nician only. User maintenance is to be restricted to fre-
quent air filter changes and to ensure the warnings and
notices found elsewhere in this manual be followed. We
recommend that at a minimum system maintenance be
performed by a qualified service technician prior to the
beginning of each heating season, and if equipped with air
conditioning, prior to air conditioning season.
P
ERSONAL INJURY OR DEATH MAY RESULT FROM IMPROPER
MAINTENANCE PERFORMED BY UNTRAINED PERSONNEL
INSTALLING DEALER OR OTHER QUALIFIED SERVICE COMPANIES TO
PERFORM THE MAINTENANCE INSPECTION