SCHEDULED MAINTENANCE

HIGH VOLTAGE
D
ALL
ISCONNECT
POWER BEFORE SERVICING OR
M
INSTALLING THIS UNIT.
ULTIPLE POWER SOURCES MAY
F
BE PRESENT.
AILURE TO DO SO MAY CAUSE PROPERTY
DAMAGE, PERSONAL INJURY OR DEATH.
CAUTION
I
F YOU MUST HANDLE THE ITNITOR, HANDLE WITH CARE.
THE IGNITOR BODY WITH BARE FINGERS, ROUGH HANDLING, OR
VIBRATION COULD RESULT IN EARLY IGNITOR FAILURE.
QUALIFIED SERVICER SHOULD EVER HANDLE THE IGNITOR.

ANNUAL INSPECTION

The furnace should be inspected by a qualified installer, or
service agency at least once per year. This check should be
performed at the beginning of the heating season. This will
ensure that all furnace components are in proper working
order and that the heating system functions appropriately. Pay
particular attention to the following items. Repair or service
as necessary.
• Flue pipe system. Check for blockage and/or leakage.
Check the outside termination and the connections at
and internal to the furnace.
• Combustion air intake pipe system (where applicable).
Check for blockage and/or leakage. Check the outside
termination and the connection at the furnace.
• Heat exchanger. Check for corrosion and/or buildup
within the heat exchanger passageways.
• Burners. Check for proper ignition, burner flame, and
flame sense.
• Drainage system. Check for blockage and/or leakage.
Check hose connections at and internal to furnace.
• Wiring. Check electrical connections for tightness and/
or corrosion. Check wires for damage.
• Filters.

AIR FILTER

WARNING
N
EVER OPERATE FURNACE WIHTOUT A FILTER INSTALLED AS DUST
AND LINT WILL BUILD UP ON INTERNAL PARTS RESULTING IN LOSS OF
EFFICIENCY, EQUIPMENT DAMAMGE, AND POSSIBLE FIRE.
Filters must be used with this furnace. Filters do not ship
with these furnaces but must be provided by the installer for
proper furnace operation.
Remember that dirty filters are the most common cause of
inadequate heating or cooling performance.
42
WARNING
T
OUCHING
O
NLY A
Maintenance
Improper filter maintenance is the most common cause of
inadequate heating or cooling performance. Filters should
be cleaned (permanent) or replaced (disposable) every two
months or as required. It is the owner's responsibility to keep
air filters clean. When replacing a filter, it must be replaced
with a filter of the same type and size.

Filter Removal

Depending on the installation, differing filter arrangements
can be applied. Filters can be installed in the central return
register, the bottom of the blower compartment (upflow only).
A media air filter or electronic air cleaner can be used as an
alternate filter. The filter sizes given in the Product Design
section of this manual or the product Specification Sheet must
be followed to ensure proper unit performance. Refer to the
following information for removal and installation of filters.
FILTER REMOVAL PROCEDURE
Media Air Filter or Electronic Air Cleaner Removal
Follow the manufacturer's directions for service.
Horizontal Unit Filter Removal
Filters in horizontal installations are located in the central
return register.
INDUCED DRAFT AND CIRCULATION BLOWERS
The bearings in the induced draft blower and circulator blower
motors are permanently lubricated by the manufacturer. No
further lubrication is required. Check motor windings for
accumulation of dust which may cause overheating. Clean
as necessary.
Filter Sizing Chart
Model
Minimum Recommended Filter Size^
*MEC960303AN*
1 - 16 X 25 Side or 1 - 14 X 25 Bottom
*MEC960403AN*
1 - 16 X 25 Side or 1 - 14 X 25 Bottom
*MEC960603AN*
1 - 16 X 25 Side or 1 - 14 X 25 Bottom
*MEC960302BN*
*MEC960402BN*
*MEC960603BN*
*MEC960803BN*
*MEC960804CN*
*MEC961004CN*
*MEC961005CN*
1 - 20 X 25 Bottom / 2 - 16 X 25 Side Return
*MEC961205DN*
1 - 20 X 25 Bottom / 2 - 16 X 25 Side Return
*CEC960403BN*
*CEC960603BN*
*CEC960803BN*
*CEC961005BN*
^ Larger filters may be used, filters may also be centrally located
1 - 16 X 25 Side or Bottom
1 - 16 X 25 Side or Bottom
1 - 16 X 25 Side or Bottom
1 - 16 X 25 Side or Bottom
1 - 16 X 25 Side or Bottom
1 - 16 X 25 Side or Bottom
2 - 10 X 20 or 1 - 16 X 25 Top Return
2 - 10 X 20 or 1 - 16 X 25 Top Return
2 - 10 X 20 or 1 - 16 X 25 Top Return
2 - 14 X 20 or 1 - 20 X 25 Top Return