5-9. Connecting To Remote 14 Receptacle RC14

LDR-14 long
distance remote
(includes 120 V
receptacle)
p
)
*The remaining sockets are not used.
Notes
OM-4433 Page 26
OR
OR
803 562
Socket*
A
24 VOLTS AC
24 VOLTS AC
B
C
D
REMOTE
OUTPUT
OUTPUT
CONTROL
E
I
115 VOLTS AC
J
F
H
K
GND
NEUTRAL
G
Work like a Pro!
Pros weld and cut
Socket Information
24 volts ac. Protected by sup-
plementary protector CB8.
Contact closure to A completes
24 volt ac contactor control
circuit.
Output to remote control:+10
volts dc in MIG mode; 0 to +10
volts dc in Stick or TIG mode.
Remote control circuit common.
DC input command signal: 0 to
+10 volts from min. to max. of
remote control with Voltage/
Amperage Adjust control at
max.
115 volts, 10 amperes, 60 Hz
ac. Protected by supplementary
protector CB7.
Contact closure to I completes
115 volt ac contactor control
circuit.
Current feedback: 1 volt per
100 amperes.
Voltage feedback: 1 volt per 10
arc volts.
Chassis common.
Circuit common for 24 and 115
volt ac circuit.