Connecting To Remote Amperage Adjust Receptacle Rc13 On Cc Models; Connecting To Remote 14 Receptacle Rc14 On Cc/Cv Models - Miller Electric Big Blue 602P Owner's Manual

Engine driven welding generator
Hide thumbs Also See for Big Blue 602P:
Table of Contents

Advertisement

5-10. Connecting To Remote Amperage Adjust Receptacle RC13 On CC Models

5-11. Connecting To Remote 14 Receptacle RC14 On CC/CV Models

New! LDR-14 long
New! LDR-14 long
distance remote
(includes 120 V
receptacle)
receptacle)
*The remaining sockets are not used.
OM-491 Page 22
1
OR
802 169-F
Return To Table Of Contents
1
Connect optional remote control to
RC13 (see Section 6-3).
Socket*
A
24 VOLTS AC
24 VOLTS AC
B
C
D
REMOTE
OUTPUT
OUTPUT
CONTROL
CONTROL
E
I
115 VOLTS AC
J
K
GND
NEUTRAL
G
Remote Amperage Adjust
Receptacle RC13
Ref. 154 862-A / 048 720-K / 802 160-E
Socket Information
24 volts ac. Protected by circuit
breaker CB5.
Contact closure to A completes
24 volt ac contactor control
circuit.
Output to remote control:+10
volts dc in MIG or Stick mode;
0 to +10 volts dc in TIG mode.
Remote control circuit common.
DC input command signal: 0 to
+10 volts from min. to max. of
remote control with Voltage/
Amperage Adjust control at
max.
115 volts, 10 amperes, 60 Hz
ac. Protected by circuit breaker
CB6.
Contact closure to I completes
115 volt ac contactor control
circuit.
Chassis common.
Circuit common for 24 and 115
volt ac circuit.