Section 5 − Installation; Installing Welding Generator - Miller Electric Legend 301 G Owner's Manual

Engine driven welding generator
Hide thumbs Also See for Legend 301 G:
Table of Contents

Advertisement

5-1. Installing Welding Generator

Movement
Location
Mounting
Inadequate support.
Y Do not use flexible mounts.
2
Grounding
GND/PE
Airflow Clearance
18 in
(460 mm)
18 in
(460 mm)
SECTION 5 − INSTALLATION
Y Do not lift unit from end.
OR
OR
1
3
Electrically bond generator frame to
vehicle frame by metal-to-metal contact.
Y Bed liners, shipping skids, and some running
gears insulate the welding generator from the
vehicle frame. Always connect a ground wire
4
from the generator equipment grounding termi-
nal to bare metal on the vehicle frame as shown.
18 in
(460 mm)
18 in
(460 mm)
OR
OR
18 in
(460 mm)
Y Do not weld on base. Welding
on base can cause fuel tank fire
or explosion. Bolt unit down
using holes provided in base.
Y Always securely fasten weld-
ing generator onto transport
vehicle or trailer and comply
with all DOT and other applica-
ble codes.
Y Do not mount unit by support-
ing the base only at the four
mounting holes. Use cross-
supports to adequately sup-
port unit and prevent damage
to base.
Y Always
ground
generator
frame to vehicle frame to pre-
vent electric shock and static
electricity hazards.
Y If unit does not have GFCI re-
ceptacles, use GFCI-protected
extension cord.
Mounting:
1
Cross-Supports
Mount unit on flat surface or use
cross-supports to support base.
Grounding:
2
Equipment Grounding Terminal
(On Front Panel)
3
Grounding Cable (Not Supplied)
4
Metal Vehicle Frame
Connect
cable
from equipment
ground terminal to metal vehicle
frame. Use #10 AWG or larger insu-
lated copper wire.
install2 5/03 − Ref. 800 652 / Ref. 800 477-A / 803 274
OM-4411 Page 15

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents