Download Print this page

Cabinet And Duct Dimensions; Ratings & Physical / Electrical Data - Coleman TG8S Technical Manual

Gas-fired residential single stage multi-position gas furnaces standard & low nox models

Advertisement

363658-CTG-C-0708
LEFT SIDE
28.5"
29.5"
24.38"
.5"
B
.5"
20"
SUPPLY END

Cabinet and Duct Dimensions

Models
CFM (m
TG(8,L)S040A08MP11
TG(8,L)S060A10MP11
TG(8,L)S060A12MP11
TG(8,L)S080B12MP11
TG(8,L)S080C16MP11
TG(8,L)S080C22MP11
TG(8,L)S100B12MP11
TG(8,L)S100C16MP11
TG(8,L)S100C20MP11
TG(8,L)S120C16MP11
TG(8,L)S120C20MP11
TG(8,L)S130D20MP11
Ratings & Physical / Electrical Data
Input Output
Models
MBH
TG(8,L)S040A08MP11
40
TG(8,L)S060A10MP11
60
TG(8,L)S060A12MP11
60
TG(8,L)S080B12MP11
80
TG(8,L)S080C16MP11
80
TG(8,L)S080C22MP11
80
TG(8,L)S100B12MP11
100
TG(8,L)S100C16MP11
100
TG(8,L)S100C20MP11
100
TG(8,L)S120C16MP11
120
TG(8,L)S120C20MP11
120
TG(8,L)S130D20MP11
130
Nominal external static pressure is 0.50" w.c. at furnace outlet ahead of cooling coils.
Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures.
Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes.
2
Vent Connection
Outlet
Electrical
Entry
Gas Pipe
Entry
Thermostat
Wiring
4" Diameter
Vent Connection
Outlet
C
Nominal
Cabinet
3
Size
/min)
800
A
1000
A
1200
A
1200
B
1600
C
2200
C
1200
B
1600
C
2000
C
1600
C
2000
C
2000
D
Air Temp.
Rise
AFUE
MBH
°F
32
80.0
25-55
48
80.0
25-55
48
80.0
30-60
64
80.0
35-65
64
80.0
25-55
64
80.0
25-55
80
80.0
40-70
80
80.0
35-65
80
80.0
25-55
96
80.0
40-70
96
80.0
30-60
104
80.0
35-65
FRONT
Electrical
Entry
Vent
Connection
Outlet
Gas Pipe
Entry
33"
Thermostat
Wiring
A
Cabinet Dimensions (Inches)
A
14 1/2
13 3/8
14 1/2
13 3/8
14 1/2
13 3/8
17 1/2
16 3/8
21
19 7/8
21
19 7/8
17 1/2
16 3/8
21
19 7/8
21
19 7/8
21
19 7/8
21
19 7/8
24 1/2
23 3/8
Max. Outlet
Blower
Blower
Air Temp
°F
HP
Amps
155
1/5
2.1
9 x 8
155
1/3
3.8
9 x 8
160
1/3
4.8
11 x 8
165
1/3
4.8
11 x 8
155
1/2
7.5
11 x 10
155
1
14.5
11 x 11
170
1/3
4.8
9 x 8
165
1/2
7.5
11 x 10
155
1
14.5
11 x 11
170
1/2
7.5
11 x 10
160
1
14.5
11 x 11
165
1
14.5
11 x 11
RIGHT SIDE
23"
B
24.25"
RETURN END
B
C
10.3
10.3
10.3
11.8
13.6
13.6
11.8
13.6
13.6
15.8
15.8
17.5
Max
Total Unit
Over-Current
Size
Amps
Protect
10
4.5
10
6.0
10
7.0
10
7.5
15
10.0
20
16.0
10
7.5
15
10.0
20
17.0
15
10.0
20
17.0
20
17.0
Johnson Controls Unitary Products
14"
1"
1.5"
.5"
.5"
Approximate
Operating Weights
Lbs
89
91
94
103
114
119
108
118
122
123
129
135
Min. wire Size
(awg) @ 75 ft
one way
14
14
14
14
14
12
14
14
12
14
12
12

Advertisement

loading

This manual is also suitable for:

Tgls