TECHNICAL GUIDE
95.5% SINGLE STAGE
GAS-FIRED RESIDENTIAL
MULTI-POSITION GAS FURNACES
MODELS: TG9S
NATURAL GAS
40 - 130 MBH INPUT
Due to continuous product improvement,
specifications are subject to change without notice.
Visit us on the web at www.york.com for the most
up-to-date technical information.
Additional efficiency rating information can
be found at www.gamanet.org.
WARRANTY
Lifetime limited warranty on the heat exchanger.
10-year heat exchanger warranty on commercial applications.
5-year limited parts warranty.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
EFFICIENCY
RATING
CERTIFIED
ISO 9001
Certified Quality
Management System
DESCRIPTION
These compact units employ induced combustion, reliable hot
surface ignition and high heat transferaluminized tubular heat
exchangers. The units are factory shipped for installation in
upflow or horizontal applications and may be converted for
downflow applications.
These furnaces are designed for residential installation in a
basement, closet, alcove, attic, recreation room or garage and
are also ideal for commercial applications. All units are factory
assembled, wired and tested to assure safe dependable and
economical installation and operation.
These units are Category IV listed and may be vented either
through side wall or roof applications using approved plastic
combustion air and venr piping.
FEATURES
Easily applied in upflow, horizontal left or right, or downflow
installation with minimal conversion necessary.
Compact, easy to install, ideal height 33" tall cabinet.
Blower-off delay for cooling SEER improvement.
Easy access to controls to connect power/control wiring.
Built-in, high level self diagnostics with fault code displays
standard on integrated control module for reliable
operation.
Low
unit
amp
requirement
application.
Single wire twinning or staging feature available.
All models are convertable to use propane (LP) gas.
Electronic Hot Surface Ignition saves fuel cost with
increased dependability and reliability.
100% shut off main gas valve for extra safety.
4 speed, direct drive PSC motor.
24V, 40 VA control transformer and blower relay supplied
for add-on cooling.
Hi-tech tubular aluminized steel primary heat exchanger.
Secondary heat exchanger made of corrosion resistant
stainless steel materials.
Timed on, adjustable off blower capability for maximum
comfort.
Blower door safety switch.
Solid removable bottom panel allows easy conversion.
Airflow leakage less than 1% of nominal airflow at
ductblaster conditions.
No knockouts to deal with, making installation easier.
Movable duct connector flanges for application flexibility.
Quiet inducer operation.
Inducer rotates for easy conversion of venting options.
Fully supported blower assembly for easy access and
removal of blower.
External air filters used for maximum flexibility in meeting
customers IAQ needs.
Protection included from air intake, exhaust vent, or
condensate blockage.
Venting applications - may be installed as either 2-pipe
(sealed combustion) or single-pipe vent (using indoor
combustion air).
No special vent termination required.
1/4 turn knobs provided for easy door removal.
Internal condensate trap design (patent pending) provides
condensate management options, easy visual operation,
and is self-priming to prevent nuisance problems.
400992-CTG-C-0209
for
easy
replacement

Advertisement

loading

Summary of Contents for Coleman TG9S040A08MP11

  • Page 1 400992-CTG-C-0209 DESCRIPTION These compact units employ induced combustion, reliable hot surface ignition and high heat transferaluminized tubular heat exchangers. The units are factory shipped for installation in upflow or horizontal applications and may be converted for downflow applications. These furnaces are designed for residential installation in a basement, closet, alcove, attic, recreation room or garage and are also ideal for commercial applications.
  • Page 2: Left Side

    RETURN END SUPPLY END Cabinet & Duct Dimensions Approximate Cabinet Dimensions (Inches) Nominal Cabinet Operating Weights Models Size CFM (m /min) TG9S040A08MP11 14 1/2 13 3/8 11 3/4 TG9S060A10MP11 1000 14 1/2 13 3/8 11 3/4 TG9S060B12MP11 1200 17 1/2...
  • Page 3: Filter Performance

    400992-CTG-C-0209 FILTER PERFORMANCE SIDEWALL VENT TERMINATION KIT - S1-1HT0901 (3") The airflow capacity data published in the “Blower Perfor- S1-1HT0902 (2") mance” table listed above represents blower performance For use on sidewall, two-pipe installations only. Provide a more WITHOUT filters. attractive termination for locations where the terminal is visable All applications of these furnaces require the use of field on the side of the home.
  • Page 4 Blower Performance CFM - Any Position (without filter) - Bottom Return Bottom Airflow Data (SCFM) Models Speed Ext. Static Pressure (in. H2O) High 1128 1077 1035 Medium High TG9S040A08MP11 Medium Low High 1360 1290 1230 1165 1103 1043 Medium High 1251...
  • Page 5 Blower Performance CFM - Any Position (without filter) - Left Side Return Left Side Airflow Data (SCFM) Models Speed Ext. Static Pressure (in. H2O) High 1131 1091 1053 1003 Medium High TG9S040A08MP11 Medium Low High 1431 1375 1304 1244 1178 1109 1040 Medium High...
  • Page 6 NOTES Subject to change without notice. Printed in U.S.A. 400992-CTG-C-0209 Copyright © 2009 by Johnson Controls, Inc. All rights reserved. Supersedes: 400992-CTG-B-0708 Johnson Controls Unitary Products 5005 York Drive Norman, OK 73069...

This manual is also suitable for: