Dometic EA 3080 Service Manual page 24

Table of Contents

Advertisement

Figure 90
- Secure temperature controller on boiler-tube of aggregate with 2 screws.
Pull protecting socket onto the end of outer securing screw of temperature
controller, because the sharp end of screw can cause an accident.
(Figure 93,94)
Figure 93
-
Reassemble
disassembly.
-
Reinsert electrical connections of temperature controller according to the
status prior to disassembly.
-
Screw wire clamp back on.
-
Reinsert electrical cover, secure with screw.
-
Push drain water evaporator onto fluid heat-exchange pipe.
Make sure the drain water outlet pipe's outlet portion reaches in the drain
water evaporator. (Figure 95)
Figure 95
Figure 91
aggregate
and
24
Figure 92
Figure 94
heating
element
in
opposite
order