Vesta log fire manual & remote operated models (20 pages)
Summary of Contents for Verine Carmelo 1150 NHWV00RN NG
Page 1
Carmelo 1150 Inset Fire MODEL NUMBERS: NHWV00RN (NG) & NHWV00RP (LPG) INSTALLATION, USER AND SERVICING INSTRUCTIONS THESE INSTRUCTIONS SHOULD BE RETAINED BY THE USER FOR FUTURE REFERENCE THIS APPLIANCE MEETS THE REQUIREMENTS OF THE EUROPEAN GAS DIRECTIVE Model No. NHWV00RN for use with natural gas (G20) at a supply pressure of 20mbar. Model No.
Installation & Service Record Please ensure that installer completes the installation record below INSTALLATION RECORD Appliance Supplied by: …………………………..Installation Date: ……………Serial No.: ….……... Installed By: …………..…...CORGI No.: …..…… Signed by Installer: ………………………..… RECORD OF 1 SERVICE RECORD OF 2 SERVICE Serviced by: …………...
Contents Page No. Installation & Service Record List of components Appliance Data ENERAL NSTALLATION EQUIREMENTS Fitting the Appliance Fitting the firebox Filling the Burner Placing of Decorative Refractory Shapes OMMISSIONING Check for spillage Briefing the User SERS UIDE Useful tips & recommendations Operation of the fire Lighting the Appliance Cleaning the fire...
Before fitting this appliance, ensure that the following components are enclosed Upper & Lower Firebox complete with burner and controls. Installation, Servicing & Users Instructions 1 Packet of Burner fill granules Roll of sealing tape 1 Handset Control unit, 1 Power Supply Unit. Flue Gather and fixings 1 Pair Legs with adjustable feet.
Page 5
which are large enough or can be altered to accept this appliance. The fireplace should be made from or lined with non-combustible material. The appliance dimensions are shown in Figure 1. If the fireplace has to be altered a lintel may be required to support the masonry over the opening.
Page 6
This appliance may be connected to an ‘Exhausto’ power flue system where no suitable chimney is available. Details may obtained from Exhausto Ltd., Unit 3, Lancaster Court, Coronation Road, Cressex Business Park, High Wycombe, HP12 3TD Tel; 01494 465166. The ‘Post Purge’ option must be selected when setting up the system.
plate and then the plate can be fixed in place with the four self tapping screws supplied. Fitting the Firebox Check that the fireplace is of the correct size or has been modified to accept the selected firebox. (See Figure 1). It is recommended that, before proceeding further, a simple smoke test be performed to check the condition of the chimney.
Page 8
into the rear and bottom of the lower firebox. Slide the firebox into the opening. If a decorative infill panel is going to be used and is not yet in place make sure that the firebox flange clears the front face of the fire opening by the thickness of the infill panel.
Filling the Burner WARNING This product uses fuel effect pieces containing Refractory Ceramic Fibre (RCF), which are man-made vitreous silicate fibres along with fibrous glass and mineral wool. Excessive exposure to these materials may cause temporary irritation to eyes, skin and respiratory tract; consequently, it makes sense to take care when handling these articles to ensure that the release of dust is kept to a minimum.
Briefing the User Demonstrate the full operation of the appliance to the customer, referring them specifically to the ceramic granules, any decorative ceramic shapes and the removal of soot as described in these instructions. Inform the customer that all cleaning procedures should be carried out only when the appliance is cold.
Operation of the fire It should be noted that your fire is fitted with a Flame Supervision Device, which cuts off the gas supply to your fire if, for any reason the pilot light is extinguished. It also monitors constantly the oxygen in the room. The pilot flame heats the thermocouple probe and allows gas to flow to the burners.
Adjusting the Flame Height To lower the flame height press and hold the DOWN BUTTON until the flame is at the desired height. To turn the main burner off and just leave the pilot burner alight continue to press and hold the down button until the main burner does out. To re- light the main burner press and hold the SMALL BUTTON and UP BUTTON together until the flame is at the desired height.
ERVICE AND AINTENANCE WARNING This product may use fuel effect pieces containing Refractory Ceramic Fibre (RCF). This material contains man-made vitreous silicate fibres along with fibrous glass and mineral wool. Excessive exposure to these materials may cause temporary irritation to eyes, skin and respiratory tract; consequently, it makes sense to take care when handling these articles to ensure that the release of dust is kept to a minimum.
Spare Parts List In the event of a part requiring replacement the parts list is as follows Part Description Part Number Electronic Control & Remote Handset G6R-PISOA5A0S5 Motorised Control Valve GV60M1C5A0D5K10L Oxypilot (NG models) Seagas P4-61 Oxypilot (LPG models) Seagas P4-58 B-112070 Issue 3 BFM Europe Limited...
Need help?
Do you have a question about the Carmelo 1150 NHWV00RN NG and is the answer not in the manual?
Questions and answers