Cleaning The Water Inlet Filters - Miele NOVOTRONIC W 1612 Operating Instructions Manual

Miele washer user manual
Table of Contents

Advertisement

Cleaning the water inlet filters

The water inlet valves are protected by
two filter screens. They need to be
checked approx. every 6 months. If
there are frequent interruptions to the
water network, they may need to be
checked more frequently.
Cleaning the filter in union of the
inlet hose
^ Close the tap and unscrew the
threaded union that connects the free
end of the inlet hose to the stopcock.
^ Remove the rubber seal 1 from the
recess.
^ Use flat pliers to grasp the plastic
filter piece 2, then remove the filter.
^ Clean the filter. Reverse the
instructions to re-insert the filter and
seal.
Cleaning and care
To clean the filter in the water inlet
valve
^ Use adjustable pliers to carefully
loosen the ribbed plastic nut on the
inlet valve and unscrew.
^ Use flat pliers to pull the filter out by
the fin, and clean it. Reverse the
instructions to re-insert and secure
the parts.
Both filters MUST be re-inserted
after cleaning.
33