Jenn-Air's ventilation
system is designed to capture both cooking fumes and smoke
while grilling.
If the system does not, these are some ducting installation situations to
check:
6" diameter round or 31/4" x 10" rectangular ducting should be used for duct lengths
10'-60'. Note: 5" diameter round ducting must be used if the duct length is 10'
or Jess.
No more than three 90 ° elbows should be used. Distance between elbows should
be at least 18".
Recommended Jenn-Air wall cap should be used. Make sure damper moves freely
when ventilation system is operating.
• There should be a minimum clearance of 8" for eooktop installed near a side wall.
If there is not an obvious improper installation, there may be a concealed problem such
as a pinched joint, obstruction in the pipe, etc. Installation is the responsibility of the
and questions should be addressed first by the installer.
The installer should
very carefully check the ducting installation instructions.