Sharp LC-32D65E Service Manual page 57

Hide thumbs Also See for LC-32D65E:
Table of Contents

Advertisement

MONITOR ERR STBY table
Outline:
Communication/Power failure detected by the monitor microprocessor (IC2003) is stored on EEPROM, and the last 4 abnormal
states can be confirmed in the adjustment process mode.
Location:
Page 1/16 of the adjustment process mode: MONITOR ERR CAUSE
"0" if there is no error. It is cleared to 0 on the last page of the adjustment process mode.
Display
02
Start-up communication error 2
03
Start-up communication error 3
04
Start-up communication error 4
05
Start-up communication error 5
06
Start-up communication error 6
07
Start-up communication error 7
08
Start-up communication error 8
09
Start-up communication error 9
0A
Communication error A
0B
Communication error B
0C
Communication error C
0D
Communication error D
0E
Communication error E
0F
Communication error F
11
Communication error H
16
Panel-related error
1A
Other error 2
1D
Power supply error 1
1E
Power supply error 2
1F
Power supply error 3
21
Power supply error 5
23
Other error 3
LED flashing timing chart at the time of the error
1) Power LED
Error type
Power LED operation (1 cycle)
H: Red on
Inverter/Lamp fail-
ure
Red flashes once
L: Off
H: Red on
Power failure
Red flashes twice
L: Off
H: Green on
Communication
failure with main
CPU
Green flashes
once
L: Off
H: Green on
Others
Green flashes
twice
L: Off
s
1.5sec
300m
Error description
Initial communication from the main CPU is not received.
Only the initial communication is received.
Until panel information request reception
Until initialization completion reception
Until version notification transmission
Until start-up information notification transmission
Until start-up information response reception
Until time-out setting reception
REQ time-out
Restart time-out during the beginning of time acquisition start-up
Ending sequence time-out
Preset start-up time-out during completion
Download start-up time-out
Time acquisition time-out
Regular communication time-out
Lamp failure
Monitor temperature failure
PS_ON(AC_DET) failure
D_POW(DET_12V) failure
D_POW(DET_D3V3) failure
Panel power failure
Error standby request from the main CPU
Note: Pins are monitor microprocessor pins (IC2003).
Refer to "Inverter/Lamp failure details". OPC_LED flashes by pressing the
[MENU] key on the remote control.
Refer to "Power failure details". OPC_LED flashes by pressing the [MENU]
key on the remote control.
Refer to "Communication failure details". OPC_LED flashes by pressing the
[MENU] key on the remote control.
Communication line failure or main CPU communication failure.
Refer to "Other failure details". OPC_LED flashes by pressing the [MENU]
key on the remote control.
4 – 18
LC-32D65E/RU, LC-37D65E/RU

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lc-32d65ruLc-37d65eLc-37d65ru

Table of Contents