Now start...
With range
hood in kitchen.
Property Damage
*Slide cardboard
or hardboard
under range before moving
range across floor.
Failure to do so could cause
damage to floor covering.
-Cover countertop,
cooktop or
set-in range with a thick,
protective
covering.
Failure to do so may result in
properly damage.
1
Disconnect
and move
n
freestanding
range from
cabinet
opening
to provide
easier
access to upper cabinet
and rear
wall.
Put a thick, protective
covering
over cooktop,
set-in range
or countertop
to protect
from
damage
or dirt.
2
Determine
which
venting
l
method
(roof or wall venting)
you need to use.
For rectangular
venting,
remove
only the
3-l/4'
x 10' rectangular
openlng
knock-
out for the venting
method
you have
selected.
3
Remove
knockout
from the wiring
H opening
(top or rear) to be used.
Remove
terminal
box cover
from range hood.
.---
- .---
Personal Injury Hazard
I
More than one person is required
to help with appliance
installation
because of its weight and size.
Failure to follow these instructions
may result in personal injury.
keyhole
slot
front
of hood
5
Lift the range hood into final
n
position
and center.
Mark on
underside
of cabinet
the location
for the
four keyhole
mounting
slots. Set range
hood aside on a protected
surface.
6 8
Determine
and clearly
mark a vertical
centerline
on the wall and cabinet
in
the area the vent opening
will be
made.
7
n
To wire through top,
mark a line 7- l/2"
from the right of the centerline
on the
underside
of the cabinet.
Mark the
point on this line that is l-3/8" from the
back wall. Drill a l- l/4" diameter
hole
through
cabinet
ut this point.
To wire through rear,
mark a line 7- l/2"
from the right of the centerline
on the
wall. Mark the point on this line that is
&l-5/8" from the floor (or l-3/8" from
underside
of cabinet).
Drill a l- l/4"
diameter
hole through
wall at this point.
c
8
To vent through the roof with 7"
n
round ductwork.
mark 5 l/8'
and 5-7/8' In from back wall al&g
the
centerline
on underslde
of cabinet.
Use
these points as centers to draw 7-l /8'
circles on underside
of cabinet.
Use a saber saw to cut the openings
for
the ductwork.
Repeat for the underside
of the top of the cabinet.
This will create
slotted openings.
the r&of with
G-l;4
-
3- l/4' x 10' rectangular
ductwork,
mark a line 1' and 5' from the back
wall on the underslde
of the cabinet.
Mark lines 5-l/4'
to the right and left of
the centerline
on the underslde
of
cabinet
that connect
the lines just
drawn.
Use
a
saber saw to cut a rec-
tangular
opening
for the ductwork.
Repeat
for the underslde
of the top
of the cabinet.
To vent through wall with 3-l/4" x 10"
rectangular
ductwork,
measure
from
floor 657/8"
and 62- l/4" (or l/8" and
3-3/n" down
from underside
of cabinet)
and mark on back wall. Measure
and
mark a line 5- l/4" to right and left of
centerline,
connecting
the two lines.
Use a saber saw to cut a rectangular
opening
for the ductwork.
Numbers
correspond
to steps.
9.
Install ductwork
through
the vent
opening
in upper cabinet
or wall.
Complete
venting
system according
to method
needed.
See Venting
requirements.
Use caulking
to seal
exterior wall or roof opening.
IO
If roof or wall cap does not
= have a damper, attach
rectangular
damper supplied with hood
to selected
rectangular
vent opening.
If damper
is attached
to bock of range
hood, be sure damper
hinge IS toward
the top.
If roof or wall cap does not have
a
damper and round ductwork is used,
Mall
damper
(supplied
with hood) in
ductwork
to prevent
air from flowing
back into ductwork
If roof or wall cap has a damper,
Do Not
use damper
blade supplied
with range
hood
11
Run wiring through
wall or
n
cabinets
according
to the
National
Electrlcal
Code and local
codes and ordinances.
Do Not turn on
power
until installation
is complete.
Use
caulking
to seal ceiling
or outside
wall
openlng.
12
n
Start screws in the center
of the narrow
neck of each of the four keyhole
mounting
screw slots marked
on the
cabinet
bottom.
Panel C