INSTALLATION AND CLEARANCES
FOR VENT-FREE OPERATION
WARNING: Maintain the
minimum clearances. If you can,
provide greater clearances from
floor, ceiling and adjoining wall.
MINIMUM FIREPLACE CLEARANCE TO
COMBUSTIBLE MATERIALS
Side Wall 16", Ceiling 42"
Floor 5", Front: 36"
LOG SIZING REQUIREMENTS
Minimum Firebox Size
Log
Size
Height
18"
20"
24"
20"
30"
20"
Carefully follow the instructions below. This
will ensure safe installation into a masonry,
UL127-listed manufactured fireplace or listed
vent-free firebox.
Minimum Clearances For Side Combustible
Material, Side Wall and Ceiling
A. Clearances from the side of the fireplace
cabinet to any combustible material and
wall should follow diagram in Figure 4,
page 10.
Example: The face of a mantel, bookshelf,
etc. is made of combustible material
and protrudes 3
combustible material must be 4" from the
side of the fireplace cabinet (see Figure
4, page 10).
Note: When installing your gas logs into
a manufactured firebox, follow firebox
manufacturer's instructions for minimum
clearances to combustible materials.
B. Clearances from the top of the fireplace
opening to the ceiling should not be less
than 42".
10
INSTALLATION
Front
Rear*
Depth
Width
Width
14"
28"
14"
32"
14"
40"
/
" from the wall. This
1
2
www.SuperiorFireplaces.US.com
Continued
*Minimum 16" from Side Wall
Figure 4 - Minimum Clearance for
Minimum Noncombustible Material
Clearances
If Not Using Mantel
Note: If using a mantel proceed to If Using
20"
Mantel. If not using a mantel, follow these
22"
instructions.
30"
You must have noncombustible material(s)
above the fireplace opening. Noncombustible
materials (such as slate, marble, tile, etc.) must
be at least 1/2" thick. With sheet metal, you
must have noncombustible material behind
it. Noncombustible material must extend at
least 8" up (for all models). If noncombustible
material is less than 12", you must install
the fireplace hood accessory (24" and 30"
Models Only). See Figure 5 for minimum
clearances.
Noncombustible
Material Distance
(A)
12" or more
Between 8" and 12" 24" or 30" Models:
Less than 8"
Example
Combustible to Wall
Requirements for
Safe Installation
Noncombustible mate-
rial OK.
Install fireplace hood
accessory (GA6050 or
GA6053 see Accesso-
ries, page 44).
18" Model: Noncom-
bustible material OK.
Noncombustible mate-
rial must be extended
to at least 8". See
Between 8" and 12",
above. If you cannot
extend material, you
must operate heater
with flue damper open.
*
126817-01A