Infinova V1700N-NE2 Series Installation Manual

Ip ptz domes
Hide thumbs Also See for V1700N-NE2 Series:

Advertisement

Quick Links

V1700N-NE2 Series
IP PTZ Domes Installation Guide
Wall Mounting
Over-roof Side
Wall Mounting
This manual addresses the installation procedures of Infinova V1700N-NE2 series IP domes. The domes feature
an all-in-one design and compact structure that makes its installation an easy and time-saving job.
Please familiarize yourself with the instructions and guidelines discussed in this manual before attempting to
install your IP domes.
Corner Mounting
Over-roof horizontal
Surface Mounting
indoor
Pole Mounting
Pendant Mounting
indoor
Ceiling Mounting
Ceiling Mounting
outdoor
outdoor

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the V1700N-NE2 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Infinova V1700N-NE2 Series

  • Page 1 Wall Mounting Surface Mounting This manual addresses the installation procedures of Infinova V1700N-NE2 series IP domes. The domes feature an all-in-one design and compact structure that makes its installation an easy and time-saving job. Please familiarize yourself with the instructions and guidelines discussed in this manual before attempting to...
  • Page 3: Copyright Statement

    This manual may not be reproduced in any form or by any means to create any derivative such as translation, transformation, or adaptation without the prior written permission of Infinova. Infinova reserves the right to change this manual and the specifications without prior notice. The most recent product specifications and user documentation for all Infinova products are available on our website www.infinova.com.
  • Page 4 Read this manual carefully before installation. This manual should be saved for future use. Important Safety Instructions and Warnings Electronic devices must be kept away from water, fire or high magnetic radiation. Clean with a dry cloth. Provide adequate ventilation. Unplug the power supply when the device is not to be used for an extended period of time.
  • Page 5: Table Of Contents

    Table of Contents 3.4.1 Indoor Mounting Specifications ........7 Chapter I Precautions ..............1 1.1 Be Careful During Transportation........1 3.4.2 Outdoor Mounting Specifications ......... 7 1.2 Plan Your Installation Beforehand ........1 3.4.3 Installation Procedures for Corner Mounting ....7 1.3 Pay Extra Care During Installation ........1 3.5 Pole Mounting ..............8 1.4 Take Necessary Cautions for Electrical Safety.....1 3.5.1 Indoor Mounting Specifications ........
  • Page 7: Chapter I Precautions

    In no event will whenever possible. Infinova be liable for any damage or loss arising from improper Do not use trolley wire in open area. Instead, place cables in steel transportation or storage.
  • Page 8: Chapter Ii Requirements And Connections

    There are power cable, network cable (alarm cables and audio cables optional) included in V1700N-NE2 series dome. Please connect them with relevant external devices or power supply respectively according to the labels on the cable.
  • Page 9: Chapter Iii Mounting

    2. Use a cutting tool suitable for the material of the ceiling, and cut Chapter III Mounting the circle out of the ceiling. This chapter describes the installation procedures for different mounting domes. 3.1 Ceiling Mounting Figure 3-4 Cutting the Circle out of the Ceiling 3.1.1 Indoor Mounting Specifications Below figures demonstrate the installation specifications for ceiling 3.
  • Page 10: Over-Roof Mounting

    Indoor Mounting Outdoor Mounting Figure 3-7 Installing Dome Bubble 7. Turn on the power. The dome will pan, tilt, and zoom to initiate system parameters as well as to verify the normal operation of the dome drive. After the initiation sequence, the dome will stop and be ready for Over-roof sidewall Mounting programming and operation.
  • Page 11: Installation Procedures For Over-Roof Mounting

    threads on the housing. Secure the connection with a holding screw. Sidewall Mounting Horizontal Surface Mounting Pedestal Bracket Dimensions Figure 3-10 Installing Housing Figure 3-8 4. Take out the dome drive from the dome package. (Note: dimisters are included in outdoor dome drive). The address ID 3.2.2 Installation Procedures for Over-roof Mounting and baud rate can be set via either software or DIP switch.
  • Page 12: Wall Mounting

    3.3 Wall Mounting Outdoor Mounting: 3.3.1 Specifications for Short-Arm Wall mounting Below figures demonstrate the installation specifications for short-arm wall mounting (Unit: mm). Indoor Mounting: Figure 3-15 Outdoor Long Arm Wall Mounting Figure 3-12 Indoor Short Arm Wall Mounting 3.3.3 Installation Procedures for Wall Mounting Note: When installing the dome (bracket mount), as to the usage of dustproof sponge and waterproof tape, please refer to Appendix III Outdoor Mounting:...
  • Page 13: Corner Mounting

    Indoor Mounting Outdoor Mounting Figure 3-19 Installing Dome Bubble Short-Arm Wall Mount Figure 3-17 Dimensional Diagram for Wall Mount 7. Turn on the power. The dome will pan, tilt, and zoom to initiate system parameters as well as to verify the normal operation of 2.
  • Page 14: Pole Mounting

    and secure it with eight expansion bolts. For dimensional 5. Take out the dome drive from the dome package. (Note: diagram of the bracket base, please refer to the following figure dimisters are included in outdoor dome drive). The address ID (Unit: mm).
  • Page 15: Installation Procedures For Pole Mounting

    4. Screw the upper housing onto the mount bracket. For outdoor housing, it is recommended to apply thread compound to the threads on the housing. Secure the connection with a holding screw. Holding Screw ØD R77.8 Ø218 Ø240 45 ° Outdoor mounting Holding Screw Figure 3-26...
  • Page 16: Outdoor Mounting Specifications

    Easily install your IP dome in below steps: A View 1. Place the pendant mount base at a suitable position against firm 4-Ø6.5 Through hole evenly distributing ceiling, and secure it with expansion bolts. Ø85 Ø100 For dimensional diagram of the pendant mount base, please refer to the following figure.
  • Page 17: Appendix I Dip Setting

    The address ID and baud rate can be set via either software or DIP switch. Whatever way users choose, there are 1~254 address ID available for PELCO-P/D and INFINOVA protocol. If setup via DIP switch is selected, refer to this section to make relevant settings before installing the dome.
  • Page 18 1. Setting Camera ID...
  • Page 20: Appendix Ii Assembly And Disassembly Procedures

    Appendix II Assembly and Disassembly 2. Setting Communication Baud Rate&Protocol Procedures Communication baud rate of the domes can be set via the first 2 positions of 6--position DIP Switch S1; The 3 position is used Assembly Procedures to set protocol; the 6 position is used to set RS485 terminal Line up the two tabs located on the upper side of the dome drive resistor connection status;...
  • Page 21: Appendix Iii Usage Of Dustproof Sponge

    Appendix III Usage of Dustproof Sponge Appendix IV Usage of Waterproof Tape When installing the dome (bracket mount), use the black dustproof When bracket mounting is selected, before the threaded part of sponge enclosed in the box to prevent dust from entering the dome, housing is screwed into the threaded hole of bracket, it is which may lead to failure of internal circuit board, and to prevent recommended to wrap the threaded part of housing assembly with...
  • Page 22: Appendix Ⅴ Cable Diameter Calculation And Lightning & Surge Protection

    Ⅴ Appendix Cable Diameter Calculation and Lightning & Surge Protection Relation between 24VAC Cable Diameter and Transmission Distance In general, the maximum allowable voltage loss rate is 10% for AC-powered devices. The table below shows the relationship between transmission power and maximum transmission distance under a certain specified cable diameter, on condition that the 24VAC voltage loss rate is below 10%.
  • Page 23 Lightning & Surge Protection The product adopts multi-level anti-lightning and anti-surge technology integrated with gas discharge tube, power resistor and TVS tube. The powerful lightning and surge protection barrier effectively avoids product damage caused by various pulse signals with power below 4kV, including instantaneous lightning, surge and static. However, for complicated outdoor environment, refer to instruction below for lightning and surge protection: The product features with dedicated earth wire, which must be firmly grounded.
  • Page 24 Infinova 51 Stouts Lane, Monmouth Junction, NJ 08852, U.S.A. Tel: 1-888-685-2002 (USA only) 1-732-355-9100 Fax: 1-732-355-9101 sales@infinova.com V1.1 1207...

Table of Contents