Good Faith Guidelines for TV Installations Above a Typical Gas Fireplace
TV Wall
Bracket
Fireplace
Notes:
1. These are good faith recommended clearances only and not a guarantee of compliance with all TV
manufacturers' maximum allowable operating temperatures.
2. Since every home has unique air flow characteristics and maximum allowable operating temperatures
can vary from manufacturer to manufacturer and from model to model, actual TV temperatures should
be validated at the time of each installation. TVs should not be used in situations where the actual TV
temperature exceeds the manufacturers' maximum allowable operating temperatures identified in the
TV's technical specifications. Contact the TV's manufacturer directly if you cannot locate this
information or have questions regarding the information.
3. Mantel height and depth must conform to mantle requirements specified in the fireplace installation
manual.
4.
"C" dimension taken from the top of the hood or fireplace opening.
5.
Suggestions on how to further reduce TV temperatures:
Figure 3.4. Good Faith TV Guidelines
10
Heat & Glo • MEZZO-1000-AU, MEZZO-1300-AU, MEZZO-1300ST-AU, MEZZO-1600-AU Owner's Manual • 2304-971 Rev. F • 8/15
TV on the wall
TV
Item Minimum Dimensions
A
2.5 in. (64 mm)
B
2 in. (51 mm) min to 3 in. (76 mm)
COMBUSTIBLE: 23 in. (584 mm): MEZZO-1000-
AU, MEZZO-1300-AU, MEZZO-1300ST-AU
C
COMBUSTIBLE: 27 in. (686 mm): MEZZO-1600-AU
NON-COMBUSTIBLE 11 in. (279 mm): ALL SIZES
D
Wall Brkt + TV Thickness + 2.5 in. (64 mm)
A
B
Mantel
D
C
a.
Increase "A" dimension.
b.
Increase "C" dimension, however, increasing "B" dimension beyond maximum recommended
typically results in higher temperatures.
TV recessed into the wall
B
A
C