Installation Details - York TLCC21-24FSAAAR User Manual

Mini-split air conditioner
Table of Contents

Advertisement

7. Installation details

7.1 Wrench torque sheet for installation
Outside diameter
mm
inch
φ9.52
3/8
φ12.7
1/2
φ15.88
5/8
7.2 Connecting the cables
The power cord of connect should be selected according to the following specifications sheet.
Grade
Unit
21K
24K
2
mm
2.5
2.5
7.3 Pipe length and the elevation
Pipe size
Capacity
Btu/h
GAS
21k~24K
5/8'' (φ15.88)
Caution:
Capacity is base on standard length and maximum allowance length is base of reliability.
Oil trap should be install per 5-7 meters.
9
Torque
Kg.m
4.2
5.5
6.6
Standard
length
LIQUID
(m)
7
3/8'' (φ9.52)
Max.
Max. Pipe
Elevation
length
B (m)
A (m)
10
20
Additional
refrigerant
(g/m)
65
In case that
more than 5m.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tlhc21-24fsaaar

Table of Contents