Speed Keys; Sleep Mode; Error Codes - Quantum 610 Owner's Manual

Hide thumbs Also See for 610:
Table of Contents

Advertisement

Speed Keys

There are two keys that control the speed. Press the hare key to increase the speed. Press the tortoise key to decrease the
speed. The speed setting is displayed on the speed indicator. If your power chair was programmed with a drive profile,
contact your Quantum Rehab Specialist for more information.
NOTE: We recommend that the first few times you operate your power chair, you set the speed to the slowest
setting until you become familiar with your new power chair.
Off-board Charger/Programming Socket
You may use an off-board charger to charge the power chair batteries through the 3-pin socket located on the front of the
FLIGHT. If you use an off-board charger, the charger current should not exceed 8 amps. Contact your Quantum Rehab
Specialist for more information.
WARNING! Only chargers with Neutrik NC3MX plugs should be connected to the off-board charger/
programming socket. See your Quantum Rehab Specialist for more information.
NOTE: The socket may also be used for reprogramming the FLIGHT. Contact your Quantum Rehab Special-
ist for more information.
Sleep Mode (If Enabled)
The power chair controller features a sleep mode. Sleep mode is a built-in circuit that will automatically shut off the
main power if the joystick is not moved in any direction for a period of time. This time factor is programmed into the
controller. To restore power and continue, push any key on the keypad.

Error Codes

The battery condition meter will flash error codes when the FLIGHT controller detects an abnormal condition in the
electrical system. All of the battery condition meter LEDs will flash a number of times quickly, then pause, then flash
again. The battery condition meter will continue to flash the error codes until the problem is fixed. The table below
identifies the individual error codes. If any of these error codes persist, contact your Quantum Rehab Specialist.
Error Code
Probable Cause
1
Possible stall timeout or user error
2
Battery Fault
3
Left Motor Fault
4
Right Motor Fault
5
Left Park Brake Fault
6
Right Park Brake Fault
7
FLIGHT Controller Module Fault
8
FLIGHT Power Module Fault
9
FLIGHT Communications Fault
10
Unknown Fault
11
Incompatible Controller Fault
Quantum 610
V I I .
O P E R A T I O N
www.quantumrehab.com
Possible Solution
Release the joystick
Check the batteries and cables. Try to charge the
batteries. The batteries may need to be replaced.
Check the left motor, connections, and cabling.
Check the right motor, connections, and cabling.
Check the left park brake, connections, and cabling.
Check the right park brake, connections, and cabling.
Check the communications connections and wiring.
Check the communications connections and wiring.
Check the communications connections and wiring.
Contact your Quantum Rehab Specialist.
Contact your Quantum Rehab Specialist.
39

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents