General DWS350SSQ User Manual

General DWS350SSQ User Manual

Deluxe fast response waterproof digital stem thermometer

Advertisement

DELUXE
FAST RESPONSE
WATERPROOF
DIGITAL STEM
THERMOMETER
USER'S MANUAL
DWS350SSQ
P
Please read this manual carefully and thoroughly
before using this product.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DWS350SSQ and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for General DWS350SSQ

  • Page 1 DELUXE FAST RESPONSE WATERPROOF DIGITAL STEM THERMOMETER USER’S MANUAL DWS350SSQ Please read this manual carefully and thoroughly before using this product.
  • Page 2: Key Features

    • Fast response • Plastic sheath with metal pocket clip • One button calibration WHAT’S IN THE BOX The DWS350SSQ comes in a white box along with this user’s manual. An “LR44” button battery is preinstalled in the battery compartment. OPERATING INSTRUCTIONS To begin, carefully remove and discard the clear plastic film protecting the entire oval control panel.
  • Page 3 At the factory, the DWS350SSQ was set to display temperature in °C. To switch to °F, press the °C/°F button. The thermometer will “remember” your last selection when it powers off and will resume using that unit upon restart. So if you always use the same unit, you will never have to press the °C/°F button...
  • Page 4: Specifications

    MIN/MAX memory. Resetting the MIN/MAX memory clears both values; you cannot independently reset one stored value but not the other. To calibrate the DWS350SSQ: 1. Power on the unit. 2. Insert the probe into a cup containing a slurry of crushed ice and water at least 1 in.
  • Page 5: Maintenance Tips

    Subject to certain restrictions, General will repair or replace this instrument if, after examination, the company determines it to be defective in material or workmanship.
  • Page 6: Return For Repair Policy

    This limited warranty does not apply to damages that General determines to be from an attempted repair by non-authorized personnel or misuse, alterations, normal wear and tear, or accidental damage. The defective unit must be returned to General Tools & Instruments or to a General- authorized service center, freight prepaid and insured.
  • Page 7 NOT S ______________________________________ ______________________________________ ______________________________________ ______________________________________ ______________________________________ ______________________________________ ______________________________________ ______________________________________ ______________________________________ ______________________________________ ______________________________________ ______________________________________ ______________________________________ ______________________________________ ______________________________________ ______________________________________ ______________________________________ ______________________________________...
  • Page 8 New York, NY 10013-3567 PHONE (212) 431-6100 FAX (212) 431-6499 TOLL FREE (800) 697-8665 e-mail: sales@generaltools.com www.generaltools.com DWS350SSQ User’s Manual Specifications subject to change without notice ©2014 GENERAL TOOLS & INSTRUMENTS NOTICE - WE ARE NOT RESPONSIBLE FOR TYPOGRAPHICAL ERRORS. MAN# DWS350SSQ 3/4/14...

Table of Contents