Sharp VL-PD3U Service Manual page 40

Liquid crystal digital camcorder ntsc
Table of Contents

Advertisement

!k=PD3U
S terminal
luminance
signal output
(75 Q termination)
1
Address: "OOB2" AE CVT
1
Measuring
instrument:
the data of address "OOB2" is rewritten, and the luminance
signal level (not including
sync signal) is adjusted to 700 + 1 OmVp-p.
Oscilloscope
(horizontal
sync)
1
Object:
G rey scale
1
Data variation
width:
"0000" to "OOFE"
5) White balance coarse adjustment
1
Measurement
terminal:
EE output
1
Address:
"0018" CGAIN
KR W
"OOIA" CGAIN-KB-W
1
Measuring
instrument:
Vector scope
1
Object:
G rey scale
1
Data variation
width:
"0000" to "03FF"
(1) Indication on the vector scope is observed
in the grey scale standard record state,
data of address "0018" and "001 A" are rewritten, and an adjustment
is made so that
the luminous dot is located in the position of burst ratio:
R-Y 0 I!I 5%
B-Y 0 k 5%
:6) Color gain coarse adjustment
)
Measurement
terminal:
EE output
)
Address:
"012B" CGIN RYG
"012D" CGIN BYG
"0128" CMAT RYG
"0126" CMAT BYG
b
Measuring
instrument:
Vector scope
.
Object:
Color bar chart
l
Data variation
width:
"0000" to "OOFF"
(1) The color bar chart is imaged, and the picture angle is adjusted so as to get white level
650 mV. Indication
on the vector scope is observed,
the data of address
"0126",
"0128", "012B" and "012D" are rewritten, and setting is made so that the red and blue
luminous dots are located in the following positions. The gain of vector scope must be
set on 75% amplitude point on the B-Y axis.) (The red phase is adjusted at the address
"0218", and the blue phase is adjusted at the address "0126".)
Adjustment
address
2.16 k 0.1 time (burst ratio)
:
"012B"
1.20 & 0.1 time (burst ratio)
:
"012D"
104O I!I 2O
n
"0128"
.
335" + 2O
-
"0126"
.
lo-18