2) Shifting to the normal operation
mode
Set the data for the address "OOBO" to "I'" I....
G
. . . . . . .
: ; . .
'....
FF".
This shifts the mode to the normal operation
mode.
V
Press the "CONTINUE"
key, and the "CAM ADJ" display goes out of the screen, enabling the normal operation.
(5) Camera unit adjustment
procedure
I
1. Auto focus adjustment
2. Iris basic adjustment
c
I
3. Black balance adjustment/A/F
noise adjustment
4. Iris AE adjustment
I
5. White balance coarse adjustment
1 6. Color gain coarse adjustment
7. White balance adjustment
8. Color gain adjustment
9. Auto white balance adjustment
*
The above 1. Auto-focus
function adjustment
and 2. Iris basic adjustment
are performed
in the auto-focus
function adjustment
mode, whereas the other adjustments
are made in the camera signal system adjustment
mode.
*
After completing
the auto-focus adjustment
mode, set the camera signal system adjustment
mode. (Take care that the adjustment
mode transfer address is different.)