Adjustment Of View Far Circuit; Vf Vco Adjustment - Sharp VL-PD3U Service Manual

Liquid crystal digital camcorder ntsc
Table of Contents

Advertisement

VL-PD3U
ADJUSTMENT
OF VIEW FAR CIRCUIT
I
TL8825
VF bright
I
TL8826
TL8805
TL8811
VF VCO
VF vco
VF bright
VF contrast
VFyl
(Wiring board diagram: Main2 Side A)
1. VF VCO adjustment
Test point
Address
TL8805 (HSY)
VCR ADJ 40
1 Mode
1
VCR AV input
Procedure
I I
1) Connect TL8826 to 3V.
2) Connect TL8805 to the frequency
counter, and adjust to the adjustment
standard value at address 40.
3) Open TL8826.
Adjustment
15734kHz
+ 1 OOHz
rating
1 Remark
1
Examples
l
During IC703 (E2PROM) replacement.
l
Durina IC8800 replacement.
2, VF bright adjustment
Test point
TL8811 (VG)
Address
VCR ADJ 46
Mode
VCR AV input
Procedure
1) The input signal must be 3-step wave.
2) Connect TL8825 (lC8800 pin 53) to GND.
3) Adjust the pedestal interval of waveform
of TL8811 to the specified level.
Adjustment
6.9 I?I 0.1 Vp-p
rating
Sig_center . .~.-.~.~.~.-.-.-.-.~.-.-
*
6.9fO. 1 Vp-p
Remark
Examples
GND
l
During IC703(E2PROM)
replacement.
l
During IC8800 replacement.
1041

Hide quick links: