8

MAINTENANCE

The GOLDMUND TELOS 500 amplifier usually requires no maintenance.
Always turn the power OFF before cleaning your amplifier. Use a clean, soft, damp cloth to
clean the amplifier surface. Dampen the cloth with water or a mild detergent solution.
Avoid abrasive or harsh cleansers (eg. products containing sodium carbonate).
9

TECHNICAL SPECIFICATIONS

POWER SUPPLY
Nominal Line Voltage 117 ; 234V
AC line range: 10%
Fuse 16A for 115 and 230V
10 toroidal transformers
Separated ground and earth signal
Connection between earth and ground to cancel all ground loops
Rated power consumption:
IEC 60065, 1/8 Output Power at 8 Ω: 210 W
Max power consumption:
IEC 60065 at 8 Ω /1% THD: 550 W
FRONT PANEL
2 control keys
Red led display for Over-heating, DC offset or HF protection and Overload
Green led display for Power ON, operating mode
Yellow led display for AC line connection and digital Lock
Yellow led display for Standby Mode
GOLDMUND TELOS 500 - Universal Power Amplifier - 16