Carrier 40MB*F Owner's Manual page 24

Floor console ductless split system sizes 09 to 12
Hide thumbs Also See for 40MB*F:
Table of Contents

Advertisement

Table
9-2
, Power failure.
• Power switch is off.
Fuse may have burned.
Batteries of remote controller exhausted
or other problem of controller.
Temperature is not set correctly.
° The compressor
is on 3 minute
protection mode cycle.
Refrigerant
is too low or too high.
* Air or no concentrating
gas in the refriger-
ating circuit.
Compressor
has malfunctioned.
, Voltage is too high or too low.
System circuit is blocked.
Outdoor and indoor units heat exch-
anger are dirty.
, The air filter is dirty.
Inlet/outlet of indoor/outdoor
units are blo-
cked.
Doors and windows are open.
o Sunlight shines directly on indoor unit.
* The heat resource is extremely high.
o Outdoor temperature,
is too high.
Refrigerant
leak or lack of refrige-
rant.
, Outdoor temperature
is lower than 7C
, Doors and windows not are completely
closed.
Refrigerant
leak or lack of refrigerant.
, Wait for the return of power.
• Switch on the power.
, Replace the fuse.
• Replace the batteries or check the con-
troller.
, Set the temperature
properly.
, Wait.
, Check for leaks, and recharge ref-
rigerant levels accordingly.
Vacuum and recharge refrigerant.
Repair or change compressor.
° Install manostat.
• Find reasons and address issue(s)
accordingly.
- Clean the heat exchangers.
• Clean the air filter.
• Eliminate the dirt.
, Close doors and windows.
• Arrange the curtains to shelter from
sunshine.
• Reduce heat source.
• AC cooling capacity reduces (normal).
Check leakage and recharge refrigerant.
° Use heating device.
, Close doors and windows.
, Check leakage and rightly recharge
refrigerant.
24