Motorola APX 7000 Detailed Service Manual page 145

Hide thumbs Also See for APX 7000:
Table of Contents

Advertisement

Troubleshooting Charts: RX RF Failure
RX RF Failure – Page 9
11
Measure control
voltage at TP602
Fvco too low?
VHF,7/800,UHF1
& UHF2:
<107.4 MHz
Yes
No
TP602 =
5 Vdc?
Yes
Remove Abacus
shield, SH3, and
inspect second LO
VCO.
Visual
examination
OK?
Yes
Replace
Varactor
VR602
TP602(Vdc)
TP601 (MHz) Fvco
0.00
1.47
4.16
5.00
No
TP602 = 0
Vdc?
Yes
10
Repair
No
defects
102.70
107.40
111.90
Remove IF filter shield,
112.80
SH2. Check IF filter and
LC matching networks.
No
10
Note: RF Test frequency used:
VHF: 154.275 MHz
UHF1: 424.975 MHz
UHF2: 485.075 MHz
700: 769.0625 MHz
800: 860.0625 MHz
Measured with a high impedance probe for
relative comparisons and troubleshooting only.
Actual S21 gain or loss may differ if the
test point is not 50 ohms.
12
No
Visual
inspection
OK?
Yes
Replace IF
filter, FL501.
5-41
Repair
Defects

Advertisement