5.8 Thermostat/temperature and turbidity control sensor

(a) First, remove the plinth (free-standing versions) and the
foot support (see 1.2).
(b) Enlarge the sump hooks and slide the thermostat.
(c) Remove the electrical connectors.
When replacing:
When replacing the thermostat, first lubricate the seal and then position it correctly on the sensor. Insert the
assembled parts taking care to ensure that the seal does not enter the sump.
Important: Check that the anchor tabs return to their original position!

5.9 Regeneration solenoid valve

(a) First remove the plinth (free-standing versions) and the foot support (see 1.2).
Important: The softening system will contain a quantity of water.
Before removing the solenoid valve, this water should be removed by suction.
(b) Turn the solenoid valve counter-clockwise until it exits its housing.
(c) Remove the connectors.
When replacing:
When replacing the solenoid valve, lubricate the O-ring and position it correctly on the valve; insert the valve
into the seat and turn clockwise until is locks into position.

5.10 Salt sensor (if featured)

(a) First remove the plinth (free-standing versions) and the foot
support (see 1.2).
(b) Detach the electrical connectors from the sensor.
(c) Using a tool, release the salt sensor from the water softener
and slide it downwards.