Set Points - U-Line U-3018RFOL-00 Service Manual

Modular 3000 series
Hide thumbs Also See for U-3018RFOL-00:
Table of Contents

Advertisement

General Information

Set Points

Up
Down
The Set points menu contains options to modify both the Zone and
Evap set points. Changes to the zone set point will be reflected on
the main screen. Changes to the evap set point alter the temperature
the evaporator needs to meet during a defrost cycle.
To access Set Points
1. Use Down
to select "Set Points".
2. Press Select
.
3. Use Up
and Down
To change set point
4. Press Select
, the selected set point will begin to flash.
5. use Up
or Down
to modify the value.
6. Press Select
to confirm setting.
To exit the Set Points menu use Up
and press Select
to confirm.
Factory Default
Up
Down
Factory Default will restore all settings to their factory default.
To access Factory Default
1. Use Down
to select "Factory Default".
2. Press Select
To restore settings to their factory default.
3. Use Down
to select "Restore?" and press Select
4. "Restore?" will change to "Restoring..." while settings are restored.
When restoration is complete, "Restoring..." will return to
"Restore".
To exit Factory Default use Up
press Select
to confirm.
14
RETURN TO MENU
SET POINTS
ZONE = 38°F
EVAP = 42°F
to scroll through available set points.
to select "Return to Menu"
RETURN TO MENU
FACTORY DEFAULT
RESTORE?
to select "Return to Menu" and
Re-Select Model
Select
Before altering model selection, U-Line customer service
must be notified. Failure to notify customer service will
result in voiding of the manufacturer warranty.
Re-Select Model allows the units model configuration to be modified.
Changing the units model completely reprograms available zones,
relay assignments, dc output assignments etc.
To access Re-Select Model
1. Use Down
2. Press Select
To alter model setting.
3. Use Down
will begin to flash.
4. Press Up
5. Press Select
To exit Re-Select Model use Up
press Select
Select
Fan Delay
The Fan Delay menu option allows the modification of fan run times
during and after a cooling cycle. In order to allow time for the
evaporator to properly cool, the evaporator fan is delayed from
starting with the cooling cycle for a given amount of time. In order to
remove as much warmth as possible from the cabinet the evaporator
fan will continue to run at the end of the cooling cycle for a given
amount of time.
Fan Delay On =
"Fan Delay On" is the amount of time in minutes the fan will be
delayed from starting from the beginning of a cooling cycle.
U-Line Service
Up
RETURN TO MENU
RE-SELECT MODEL #
3018R
Down
CAUTION
to select "Re-Select Model".
.
to select "Model=" and press Select
or Down
to scroll through each available model.
to confirm.
to select "Return to Menu" and
to confirm.
Up
RETURN TO MENU
FAN DELAY
FAN DELAY ON = 1
FAN DELAY OFF = 2
Down
Select
. "Model"
Select