Upgrading Panel Timing Controller Software - Sharp LC-32D44U Service Manual

Hide thumbs Also See for LC-32D44U:
Table of Contents

Advertisement

2.4. Upgrading Panel timing controller software

Create the USB memory for Panel timing controller software version upgrade in the same manner as explained in the "Main software version
upgrade."
Copy the file D44UAxxx.USB and D44UAxxx.TCN to USB memory.
2.4.1 How to upgrade the software
1. Unplug the AC cord.
2. Insert the USB Memory for version upgrade (prepared as above) into the service socket located Right side from center at terminals, above HDMI4
terminal in the rear of the unit.
3. Plug in the AC cord with power button pressed down after 5 seconds, unpress the power button.
4. After the unit startup, the upgrade starts. The screen is not shown. This take about a minute.
5. When there is an error, 'PANEL EEPROM' field display the type. Ignore 'UPGRADE SUCCESS' that is displayed at the top.
6. Upon completion of the whole process, the upgrade success screen as shown below appears. You can check the new software version on this
screen. The version information appears after the upgrade is complete.
7. Unplug the AC cord and remove the USB Memory for version upgrade.
8. Now the software version upgrade is complete.