Chapter 7 Troubleshooting; Power System Failure; Configuration System Failure - Huawei Quidway S3526 Installation Manual

Vrp3.10
Hide thumbs Also See for Quidway S3526:
Table of Contents

Advertisement

Installation Manual
Quidway S3526 Ethernet Switch

7.1 Power System Failure

You can check and verify whether power system of S3526 switch has failed by
observing the power indicators on the front panel. The POWER indicator is always on
when the system is normal; if the indicator is off, please check that:
Whether the switch power cords are correctly connected.
Whether the power input to the switch matches the requirement as labeled on the
switch.

7.2 Configuration System Failure

After the switch is powered on and the system is normal, the booting information will be
displayed on the configuration terminal. If the configuration system has any fault, there
will not be any screen display at the configuration terminal or the displayed characters
will be totally illegible.
I. Troubleshooting when there is no terminal display
If there is no output information after the configuration is powered on, please check
that:
whether the power supply is normal
whether the console cables are connected correctly
If no problems are found after the above-mentioned items have been checked, the
cause may lie in the console cable or the setting of the terminal (such as HyperTerminal)
parameters. Please perform the corresponding check.
II. Troubleshooting when the terminal display is illegible
If the configuration terminal display is illegible, the cause might lie in the parameter
setting error at the terminal (such as HyperTerminal).
Please confirm the parameter setting at the terminal (such as HyperTerminal): set the
baud rate to 9,600, data bit to 8, parity check to none, stop bit to 1 and flow control to
none. Select the terminal emulation as VT100.

Chapter 7 Troubleshooting

7-1
Chapter 7 Troubleshooting

Hide quick links:

Advertisement

Table of Contents
loading