5 Carriage does not operate at all, while the Alarm Lamp is on and "ERROR AUTOGAP" is displayed
on LCD.
•
Platen works normally during initialization?
Yes
No
B
The cables to PRA-Board CN1 and CN2 connected properly?
Yes
•
The cable to PMA-Board CN2 connected properly?
Yes
•
The gears existing between Auto-Gap Motor and Platen in normal position?
Yes
•
Check Auto-Gap Motor wave form at PRA-Board during initialization. No problem?
OVDV: Examine between CN2-6 pin and SH6.
ø1: Examine between CN2-4 pin and SH6.
ø2: Examine between CN2-3 pin and SH6.
ø3: Examine between CN2-2 pin and SH6.
ø4: Examine between CN2-1 pin and SH6.
No
40496501TH Draft Version
No
•
Connect the cables properly.
No
•
Connect the cable properly.
No
•
Mount the gear properly. Replace it if damaged.
•
If Auto-Gap Motor gear is broken, replace the whole Auto-Gap Motor.
Yes
•
Abnormal OVDV wave form?
Yes
No
D Replace PMA-Board. Recovered?
No
Yes
•
End
•
Replace the junction cable between PMA-Board CN2 and PRA-
Board CN1. Recovered?
No
Yes
•
End
•
Replace PRA-Board.
•
Replace PDA-Board. Recovered?
No
Yes
•
End
5-1
135