Sanyo PLC-HF15000L Service Manual page 76

Hide thumbs Also See for PLC-HF15000L:
Table of Contents

Advertisement

Electrical Adjustment
b Auto calibration (PC)
Input mode
Input 1 [RGB (PC Analog)]
Input signal
16-step gray scale computer signal
Screen size
Normal
1. Enter the service mode.
. Select Group "260", No. "100" and set data value "1".
3. Select Group "260", No. "0" and set data value "0"
to "1".
The projector begins auto-calibration and then "OK"
will appear on the screen.
4. Select Group "260", No. "100" and set data value "2".
5. Select Group "260", No. "0" and set data value "0"
to "1".
The projector begins auto-calibration and then "OK"
will appear on the screen.
6. Select Group "260", No. "100" and set data value "0".
n Auto calibration (Composite)
Input mode
Input  [Video]
Input signal
100% color bar composite video signal
Screen size
Normal
1. Enter the service mode.
. Select Group "260", No. "100" and set data value "3".
3. Select Group "260", No. "0" and set data value "0"
to "1".
The projector begins auto-calibration and then "OK"
will appear on the screen.
4. Select Group "260", No. "100" and set data value "4".
5. Select Group "260", No. "0" and set data value "0"
to "1".
The projector begins auto-calibration and then "OK"
will appear on the screen.
6. Select Group "260", No. "100" and set data value "0".
m Auto calibration (Component)
Input mode
Input  [Y,Pb/Cb,Pr/Cr]
Input signal
100% color bar component video signal
(480i)
Screen size
Normal
1. Enter the service mode.
. Select Group "260", No. "100" and set data value "5".
3. Select Group "260", No. "0" and set data value "0"
to "1".
The projector begins auto-calibration and then "OK"
will appear on the screen.
4. Select Group "260", No. "100" and set data value "6".
5. Select Group "260", No. "0" and set data value "0"
to "1".
The projector begins auto-calibration and then "OK"
will appear on the screen.
6. Select Group "260", No. "100" and set data value "0"
Common center adjustment
,
Input mode
Input 1 [RGB (PC Analog)]
Input signal
50% (R,G,B) pattern signal
1. Enter the service mode.
. Project only one color component to the screen.
Select Group "101", No. "4" and then change data val-
ue from "2" to "0".
3. Change data value to obtain the minimum flicker for
each color on screen.
Group No.
Screen
100 - 9
only green color picture
100 - 10
only blue color picture
100 - 11
only red color picture
4. Select Group "101", No. "4" and then change data val-
ue from "0" to "2".
. Gamma shipment adjustment
Software
PROJECTOR SERVICE TOOL v4.0
Use the software to obtain the proper gray scale. See the
further information of the software instruction manual.
⁄0 Ye device shipment adjustment
Software
PROJECTOR SERVICE TOOL v4.0
Use the software to obtain the proper gray scale. See the
further information of the software instruction manual.
Color shading correction adjustment
⁄1
Software
PROJECTOR SERVICE TOOL v4.0
Use the software to correct the color shading of the
screen. See the further information of the software in-
struction manual.
The color shading correction adjustment for this model
should be performed with the whole-gray patterns speci-
fied as below.
8-input patterns:
5% gray, 10% gray, 15% gray, 20% gray,
30% gray, 50% gray, 60% gray, 80% gray
Adjustments item no. [5] to [7] are carried out at the
spare parts shipment in the factory, therefore they are
not required when the main board is replaced with
new one.
-76-

Advertisement

Table of Contents
loading

Table of Contents