11.4 Connect The Cord And Cable To Mono Bloc Unit

(REFER TO WIRING DIAGRAM AT UNIT FOR DETAIL)
1
An isolating device must be connected to the power supply cable (Disconnecting means).
Isolating device (Disconnecting means) should have minimum 3.0 mm contact gap.
o
Connect the approved polychloroprene sheathed power supply 1 cord (5 x min 1.5 mm
o
supply 2 cord (3 x min 1.5 mm
IEC 57 or heavier cord to the RCCB, and to the other end of the cord to isolating device (Disconnecting
means).
2
To avoid the cable and cord being damaged by sharp edges, the cable and cord must be passed through a
bushing (located at the right hand side of the mono bloc unit) before being connected to the terminal block.
The bushing must be used and must not be removed.
3
Secure the cable onto the control board with the holder (clamper).
2
) and power supply 3 cord (5 x min 1.5 mm
43
2
) and power
2
), type designation 60245