Installation Diagram - Mitsubishi Electric MSZ-FE09NA Installation Manual

Split-type air conditioners
Hide thumbs Also See for MSZ-FE09NA:
Table of Contents

Advertisement

1-4. INSTALLATION DIAGRAM

ACCESSORIES
Check the following parts before installation.
<Indoor unit>
(1)
Installation plate
Attachment screws for the installa-
(2)
tion plate
4 × 25 mm
(3)
Remote controller holder
Screws for the remote controller
(4)
holder
3.5 × 16 mm (Black)
(5)
Battery (AAA) for (6)
(6)
Wireless remote controller
(7)
Felt tape (For left or left-rear piping)
(8)
Anti-Allergy Enzyme Filter
(9)
Platinum deodorizing filter
FIELD-SUPPLIED PARTS
(A)
Indoor/outdoor unit connecting wire*
(B)
Extension pipe
(C)
Wall hole sleeve
(D)
Wall hole cover
(E)
Pipe attachment strap
(F)
Screw for (E) 4 × 20 mm
(G)
Piping tape
(H)
Putty
Drain hose
(or soft PVC hose, 19/32 in. [15 mm]
(I)
inner diameter or hard PVC pipe
VP16)
(J)
Refrigerant oil
(K)
Power supply cord*
* Note:
Place indoor/outdoor unit connecting wire (A)
and power supply cord (K) at least 3 ft. (1 m)
away from the TV antenna wire.
Open two sides of
left, right, or rear
side.
Units should be installed by licensed contractor
according to local code requirements.
Drain piping for outdoor unit
Install the unit horizontally.
Do not use drain socket in cold regions. Drain may freeze and make the fan stop.
The outdoor unit produces condensate during the heating operation. Select the installation place to ensure to prevent the outdoor unit and/or the grounds from being wet by drain
water or damaged by frozen drain water.
1
5
1
2
2
1
1
1
1
1
1
1
1
2 to 5
2 to 5
1
1
2 to 5
1
1
Basically open 4 in.
(100 mm) or more
without any obstruction
in front and on both
sides of the unit.
4 in.
(100 mm)
or more
(B)
Use the wall hole sleeve
Indoor unit
(C) to prevent indoor/out-
door connecting wire (A)
from contacting metal
Wall hole
parts in the wall and to
sleeve (C)
protect the wiring from
rodents.
Cut off the
extra length.
After the leak test, apply insulating mate-
rial tightly so that there is no gap.
When the piping is to be attached to a wall
comprised of tin plate or metal netting, use
chemically treated wooden piece 25/32 in.
(20 mm) or thicker between the wall and
the piping, or wrap insulation vinyl tape 7
to 8 turns around the piping.
To use existing piping, perform COOL
operation for 30 minutes and pump down
before removing the old air conditioner.
Remake flare according to the dimension
for new refrigerant.
31-1/2
5-
19-11/16
15/16
Air inlet
Air outlet
×
2-3/8
13/16 slot
800
500
150
Air inlet
Air outlet
2-10
×
21 slot
Wall hole cover (D)
Seal the wall hole
gap with putty (H).
Attach the pipe to
wall with pipe at-
tachment strap (E).
Pipe attachment
strap (E)
Attachment screw (F)
Unit: inch
1-9/16
Unit: mm
40