Philips Desa DR16124 Installation Instructions Manual page 23

Table of Contents

Advertisement

. . . Continued from previous page
Ref
Name
12
Setup for all cameras - Area draw
13
Setup for all cameras - Screen size
14
Setup for all cameras - Quality
15
Setup for all cameras -
Full screen when motion
16
Dwell time
17
No full screen
18
Set quad Dwell time
Description
Creates full screen detection area for all cameras.
Configures the recording screen resolution.The recommended screen
size is 320 x 240.
NOTE: Setting a screen resolution of 160 x 120 results in an
approximate doubling of display update and recording speed, but video
quality is low. Similarly, a screen resolution of 640 x 480 results in a
slower display update and recording speed, but video quality is
excellent. An increase in resolution diminishes the record
duration.
Video quality improves as you set Quality higher, but file size per
frame of video also increases.
Default quality value is Normal.
When motion is detected, the display goes from its current setting
to full screen. Enter the camera number(s) for full screen display upon
video motion detection.
Example: To display camera inputs 1, 2, and 3 full screen when video
motion is detected for any of these cameras, enter 1,2,3 in the Full
screen when motion field.
Enter the time (in seconds) for full screen display of camera(s) when
video motion is detected.
Cancels displaying camera(s) where video motion was detected.
Sets the dwell time for quad sequencing.