If the unit does not operate to the specifications set forth in this user guide, or exhibits a distinct change in performance, this may be an indication of a problem needing repair. Environmental Operating Limits of HD Portal plus Operating Temperature: 0°C to 32°C (32°F to 90°F) Relative Humidity: 10% to 90% non-condensing Storage &...
Portal plus User Manual Version 1.5 July, 2015 Warranty MediaPOINTE, Inc. warrants that the HD Portal plus (excluding spare parts if applicable, external peripheral devices and consumables) will be free from any defect in materials or workmanship and shall perform in accordance with its specification for a period of 30 days for MediaPOINTE, Inc.
Service Support and Training . . . . . . . . . . . . . . . . . . . . . . . ii Technical Support and HD Portal plus Package Contents . . . . . . . . . . iii Warranty .
Page 7
Playback on HD Portal plus . . . . . . . . . . . . . . . . . .
Welcome to the user’s guide for the MediaPOINTE® HD • Discuss research, engineering, architecture, Portal plus. The HD Portal plus is one of the easiest product design, or process analysis when the to use, most cost-effective and reliable capture, participants are not able to meet in one central recording, streaming and archiving products on the location.
2. USB Port The USB 2.0 port on the front panel is used to transfer files to and from the HD Portal plus. The USB Port may also be used with the optional MediaPOINTE KEYCARD AUTOMATION SYSTEMS 3. WiFi System Antenna (Optional)
10/100Mb CAT-5e LAN cable to connect the HD Portal plus to a network. Audio Output The standard 3.5 mm stereo connector outputs stereo unbalanced audio from the HD Portal plus. (Unbalanced) Audio Input The standard 3.5 mm mono connector takes input (Unbalanced) from unbalanced mic or line level signals.
| HD Portal plus User Manual Version 1.5 July, 2015 CONNECTORS AND FUNCTIONS Connector Function/Name Description The 3.5 mm mini stereo connector is used IR Infrared Input to connect the included IR receiver to the unit for IR remote control. The standard serial DB-9 connector allows RS-232 Serial Port connection for serial control (Note: a null-...
Portal plus. The Author can access or change any of the settings under the “Record/Stream” section in the main To log into the HD Portal plus, browse to its IP address menu. No password is required for the “author” login as using your Internet web browser.
DHCP, the IP address will be provided IP Settings automatically and will be visible on the local output of the HD Portal plus. To set the IP address, follow the procedure on the next page. System Name The factory set system name is MediaPOINTE.
On your Internet browser, enter the current IP default of this configuration file and will implement the address of the HD Portal plus. (Note: If the unit has settings from the file. factory settings, the default static IP address is: If the dmx_ip_conf.txt file is intentionally left blank...
| HD Portal plus User Manual Version 1.5 July, 2015 Controlling the HD Portal plus MAIN SYSTEM TOOLBAR TABLE The HD Portal plus can be controlled by several different Icon Function Description methods. These include, a Web Portal interface, IR remote control, RS-232 serial port, or Telnet.
RS-232 The On-Screen Menu is displayed on the VGA or HDMI On the back of the HD Portal plus there is a serial con- output of the HD Portal plus. The HD Portal plus IR trol port configured as a DTE that supports the RS-232 remote will provide some of the configuration features protocol.
Port number (optional for non standard ports), Destination path, and credentials. You Content stored on the HD Portal plus can be viewed via can choose to delete the content after a successful the HDMI or RGBHV output connected to a local mon- upload.
| HD Portal plus User Manual Version 1.5 July, 2015 Titles & Credits EDIT PROFILE ICONS TABLE JPEG images can be uploaded to the HD Portal plus Icon Function Description in the Titles & Credits selection of the main menu.
Creating/Modifying a Profile This section describes how to set up all configurable recording options on the HD Portal plus; only author and admin users have access to these settings. 2. To create a custom profile, choose one of the two profiles outlined below in red as a starting point.
| HD Portal plus User Manual Version 1.5 July, 2015 Creating (Copy) a Profile Next, using the screen capture on the right as a guide set parameters. Fill in each section with the informa- tion you want in that profile as outlined in the steps below.
| HD Portal plus User Manual Version 1.5 July, 2015 Modifying (Edit) a Profile Modifying a profile is very similar to copying one. Use the screen capture on the right as a guide to set pa- rameters. Modify each section with the information you want in that profile as outlined in the steps below.
| HD Portal plus User Manual Version 1.5 July, 2015 Setting screen layouts You can choose a screen layout while creating or editing profiles. If you choose the Copy Icon to create a new profile, click the change button as shown below (outlined in red.) Then select the layout you want from the Screen Layouts pop up as shown at the bottom of this page.
The upload history tab shows you previously Upload uploaded files. History The HD Portal plus has the ability to test audio and video to connected output devices without the need for live input sources. There are four audio test tones Logging and three test images for confirming video output to a locally connected monitor.
Product Series Number streaming marketplace. The installed Version number of Software Version In order to keep the HD Portal plus up to date with current software all of the latest features, you may want to update Build Number Software Build Number the system software from time to time.
| HD Portal plus User Manual Version 1.5 July, 2015 Options All HD Portal plus units are shipped out to the field with the basic software installed. However, the software was designed with the ability to receive multiple option upgrades. Please contact MediaPOINTE to purchase these options.
Page 27
HD Portal plus User Manual Version 1.5 July, 2015 Technical Support 805.214.7911 support@mediapointe.com Main Office 667 Rancho Conejo Blvd. Newbury Park, CA 91320 805.480.3700 www.mediapointe.com...