Usage of RAC-12B
The RAC-12B is a memory stick to save the programming data of the cash
register(option).
To prepare for using the RAC-12B
1. Turn the register key to the "OFF" mode position.
2.
Open the slot cover on the left side of the register.
3.
After removing the RAC-12B cap, hold the RAC-12B so that the arrow on the
stick is on the top and insert it into the slot in the direction of the arrow.
4.
Close the slot cover.
5. Turn the register key to the "PGM" mode position.
6.
7 <SUB TOTAL> 2110 <SUBTOTAL> 02 <CASH/AMT TEND> <CASH/AMT TEND>
How to backup the programming data to the RAC-12B
Turn the register key to the "PGM" mode position.
7 <SUB TOTAL> 4110 <SUBTOTAL> <CASH/AMT TEND>
How to restore the programming data from the RAC-12B
Turn the register key to the "PGM" mode position.
7 <SUB TOTAL> 4100 <SUBTOTAL> <CASH/AMT TEND>
-Error code-
E200: Insert RAC
E201: Illegal Format
How to enable auto-sign off after finalization
1. Turn the register key to the "PGM" mode position.
2.
3<SUB TOTAL> 2622 <SUBTOTAL> D10~D1 <CASH/AMT TEND> <SUBTOTAL>
D4:0.........no
D4:4........yes
6