Outdoor Units
Refrigerant Type
2 = R-22
4 = R-410A
TRANE
Product Type
W = Split Heat Pump
T = Split Cooling
Product Family
Z = Leadership – Two Stage
X = Leadership
R = Replacement/Retail
B = Basic
A = Light Commercial
Family SEER
0 = 10
3 = 13
6 = 16
1 = 11
4 = 14
8 = 18
2 = 12
5 = 15
9 = 19
Split System Connections 1-6 Tons
0 = Brazed
Nominal Capacity in 000s of BTUs
Major Design Modifications
Power Supply
1 = 200-230/1/60 or 208-230/1/60
3 = 200-230/3/60
4 = 460/3/60
Secondary Function
Minor Design Modifications
Unit Parts Identifier
Air Handlers –
Residential
Refrigerant Type
4 = R-410A
2 = R-22
Application
TE = Fully Convertible
TG = Semi Convertible
TF = Front Return
TV = Vertical
Product Family
E = Leadership – Variable Speed
P = Leadership
C = Replacement/Retail
B = Basic
Flow Control
3 = Nonbleed TXV
4 = FCCV*
Feature Identifier
0 = Standard Unit
F = Air-Tite™
Nominal Capacity in 000s of BTUs
Major Design Modifications
Power Supply
1 = Single Phase
Electrical Connection
0 = Pig Tails
B = Circuit Breaker
D = Pull Disconnect
Future Option – Factory Installed Heater Nominal KW Value
Minor Design Modifications
Unit Parts Identifier
NOTE: There will be a phase-in of new model numbers for new
air handlers over next 2 years.
*Shipped with R-22 FCCV
© 2012 Trane
Model
Nomenclature
4 T W X 5 0 3 6 B 1 0 0 0 A A
4 T E E 3 F 3 6 A 1
0 0 0
G
F
as
urnaces
Furnace Configuration
TU = Upflow/Horizontal
TD = Downflow/Horizontal
Type
C = Condensing
D = Induced Draft
E = Electronic Ignition
X = Direct Vent Condensing
Y = Direct Vent Condensing Variable Speed
Heating Input MBTUH
080 = 80,000 BTUH
Major Design Change
C = Single Stage
R = Two Stage
All other = Standard System
Power Supply and Fuel
115 Volt
Natural Gas
Airflow Capacity for Cooling
Example: 36 = 3 Tons
400 CFM/Ton
400 x 3 Tons = 1200 CFM
V3 = 1 1/2 – 3 Tons, Variable Speed Motor (ICM)
V4 = 2 – 4 Tons, Variable Speed Motor (ICM)
V5 = 3 – 5 Tons, Variable Speed Motor (ICM)
Minor Design Change
Service Digit – Not Orderable
A A
Furnace Coils
Refrigerant Type
T = R-22
R = R-410A
C = Cooling only
Furnace Coils
XA = Uncased "A" Coil Upflow/Downflow
XC = Cased Coil Upflow/Downflow/Horizontal
XH = Cased Horizontal Only
CB = Cased/Brazed Upflow – Cooling Only
UB = Uncased/Brazed Upflow – Cooling Only
Coupling
0 = Braze
Nominal Capacity
Nominal Capacity in 000s of BTUs
Product Family
C = Universal
S = High Efficiency – Nonbleed TXV
E = High Efficiency – Bleed TXV
A = Upflow Only
D = Reverse Airflow
Refrigerant Control
2 = Cap Tube
3 = Nonbleed TXV
4 = Accutron™ Flow Control/Check Valve (FCCV)
5 = Bleed TXV
HP = Heat Pump
00 = Cooling only (7 1/2 to 10 ton)
Minor Design Change
Service Digit – Not Orderable
6
T
U
Y
0
8
0
R
9
V
3 W 0
T
X
C
0
2
4
C
4
H
P C
22-1800-15