Technical Information
Component Test (Service Level 2)
The Test Step is indicated by the flashing rhythm of the Soak LED
using long and short flashes. (example: long flash short
flash short flash short flash short flash short flash = 15).
Note
In addition to the flashing rhythm of the Soak LED, the active Test
Step appears in the LED Display. (Example
Drain Pump activation.
Navigation / Component Activation
Press the Start Button to advance to the desired Test Step.
After a 1 second pause, the component is energized
Cancel the Test Step
Press the Start Button to cancel the activated component; and
advance to the next Test Step (next component test).
The next component test automatically starts after another 1
second delay (see Navigation / Component Activation above).
Quitting the Service Mode (without saving)
Switch off the machine.
Note
The service mode automatically shuts off after 30 minutes.
W1113, W1119, W1203, W1213 & W1215 Clothes Washers
60
= Test Step 5 /
U5