STAND ALONE INSTALLATION
If installing this furnace as a stand alone unit, ensure all local codes and all instructions in this manual are followed, including clearance
to combustibles, fl oor protector specifi cations and safety warnings.
PARALLEL FURNACE INSTALLATION
Installing this unit in parallel with another furnace (sharing the same ductwork)
To install the new furnace in parallel with an existing furnace follow the instructions
for series installation with a few additional requirements., listed below.
 The return air will duct directly to the return of the new furnace, and not be pulling
through any other furnace.
 The output of the existing furnace must be equal to or greater than this wood furnace.
 If installing in a parallel confi guration the ductwork may need adjustments so as
to maintain the static pressure between 0.2" W.C. And 0.05" W.C.
 A back fl ow damper must be installed in the supply ductwork of the new furnace,
to ensure that air does not circulate back through the wood furnace.
 Some installation confi gurations may require dampers to be installed in the supply
ductwork of both furnaces.
SERIES FURNACE INSTALLATION
This furnace may be installed in series with an existing furnace. The transfer duct between the existing furnace and this furnace must
be at least 320in
2.
. The minimum radius on any elbows is 6". Ensure that the installation of the furnace will not allow inversion of the
air fl ow. If a divider is installed to separate the supply duct from the existing furnace and the new furnace (option 2), the divider must be
installed in a manor that is completely air tight. Only install with a supply duct divider (Option 2) if standard series installation (Option
1) is not possible. If the existing furnaces fan limit control switch is mounted in the plenum then ensure that the switch is at least 5" from
any divider necessary in the ductwork.
Do not remove, relocate or bypass any of the safety controls in the original furnace.
1) Before installation existing furnace measurements must be taken
A) Existing air fl ow (CFM)_____________
B) Existing ΔT (Temperture rise)_____________
2) Verify CFM with the calculations shown in Appendix A.
 After installing your new furnace the temperature rise (Δ T) and air fl ow (CFM) must be equal to the original measurements
3) Connect the supply duct of the existing furnace to the intake on your new furnace.
4) Connect the supply duct of your new furnace to the existing ductwork that will distribute the air throughout the house.
is not permitted in Canada.
Do not connect to a down draft furnace.
OPTION 1
taken before installation.
OPTION 2