MAINTENANCE CLEARANCES
Your furnace has recommended minimum maintenance clearance requirements. These clearances insure that there is adequate room to
preform maintenance and service your furnace. DO NOT store fuel within the specifi ed clearances. The clearances will change depending
on what kits are installed with your furnace. See the tables and diagram below to determine the clearances for your furnace.
Standard unit (no additional kits)
Dimension
H
Maintenance Clearance (Front)
J
Maintenance Clearance (Left)
K
Maintenance Clearance (Right)
L
Maintenance Clearance (Rear)
Unit with Blower Kit
Dimension
H
Maintenance Clearance (Front)
J
Maintenance Clearance (Left)
K
Maintenance Clearance (Right)
L
Maintenance Clearance (Rear)

FLOOR PROTECTOR

The furnace must be placed on solid concrete, solid masonry, or when installed on a combustible fl oor, on a fl oor protector. The
fl oor protector is required to provide heat, live ember, and ash protection and must be of a non-combustible, continuous solid surface
to protect against infi ltration of live embers and ash. Refer to fl oor protector manufacturer's instructions for installation directions.
The fl oor protector or non combustible fl oor must extend under the furnace and beyond each side as shown below.
Dimension
M*
Front
N
Flue rear
P**
Left
Q**
Right
R
Flue Side
⃰ Canadian installations require 18" (457mm)
Inch
mm
24
610
10
254
10
254
29
737
Inch
mm
24
610
24
610
24
610
36
915
Inch
mm
16*
407
2
51
8
204
8
204
2
51
L
J
H
MAINTENANCE CLEARANCE
R
P

FLOOR PROTECTOR REQUIREMENTS

K
N
R
Q
M