Electrical Installation - Golden Eagle 7000 Owner's Installation And Operation Manual

Table of Contents

Advertisement

It is recommended to connect the furnace to its own 15 amp 120 Volt circuit from the house power supply
FAN LIMIT CONTROL
Using the Honeywell mounting bracket, the fan limit control must be mounted to the supply air ductwork. Drill a 7/8" hole for the
fan limit control sensor rod to pass through into the ductwork. The center of the limit control needs to be installed 14" from the rear of
the furnace on the left side of the plenum (this is viewing the furnace from the rear). The hole needs to be drilled 7.5" from the top of
the furnace.
BLOWER FAN WIRING
Supply power to the blower fan from an independent 120 Volt circuit. The blower section is controlled through the Fan Limit Control
Switch. See the wiring diagram for details.
SERVO MOTOR

ELECTRICAL INSTALLATION

All electrical connections should be done by a qualifi ed electrician