TROUBLESHOOTING CHART
PROBLEM
PROBABLE CAUSE
11. Moisture dripping
11a.
Extreme humidity
into room
11b.
Inadequate seal
11c.
Improper level
12. Excess conden-
12. Extreme humidity
sation running out-
side
COMPRESSOR SPECIFICATIONS
Part Number
Capacity (Btu/hr)
8040122
5,160
8040126
6,745
FAN MOTOR SPECIFICATIONS
Part Number
Capacity (Btu/hr)
8040173
5,160 to 6,745
PROPER LOCATION OF THERMISTOR
The thermistor must be properly mounted on
the front surface of the evaporator.
VERTICAL LOCATION: The plastic thermistor
mounting bracket should be located on the
fourth tube from the top as shown in the illus-
tration.
HORIZONTAL LOCATION: The right end of
the plastic thermistor mounting bracket should
be located 6½" from the evaporator frame as
shown in the illustration. The end of the ther-
mistor should be located 7½" from the evapo-
rator frame.
CORRECTION
11a.
Advise customer of pos-
sible sweating formations under
abnormal conditions. Check and
improve all possible seals.
11b.
Check and improve all
sealed areas.
11c.
Check for proper side to
side level of unit. Check for (½"
rear slope (or 1 full bubble) on
level.
12. This condition is normal in
areas of extreme humidity.
Watts
Run Resistance
Start Resistance
465
1.469
2.373
615
1.130
2.712
Table 1
Hi Speed
Low Speed
Turbo Speed
32.4Ω
40.4Ω
20.4Ω
Table 2
7½"
6½"
19