GB
! Before placing your new appliance into operation please read these operating
instructions carefully. It contains important information concerning the safe
installation and operation of the appliance.
! Please keep these operating instructions for future reference. Make sure that
the instructions are kept with the appliance if it is sold, given away or moved.
! The appliance must be installed by a qualified professional in accordance
with the instructions provided.
! Any necessary adjustment or maintenance must be performed after the
cooker has been disconnected from the electricity supply.
The cookers have the following technical specifications:
Category: I2H (GB)
This appliance must be installed in accordance with the regulations in force
and only used in a well ventilated space.
The data badge is fitted on the rear panel. The model/serial number can also be
found on a badge located below the left-hand oven door beneath the door seal.
Read these instructions before installing or using the appliance and
retain them for future reference.
These instructions are only valid for the countries whose symbols
appear in the manual and on the serial number plate.
To help you make the best use of your cooker, PLEASE READ THIS
BOOKLET CAREFULLY.
Your new cooker is guaranteed and will give lasting service. The guarantee
is only applicable if the cooker has been installed in accordance with the
Installation Instructions. The cooker is designed specifically for domestic
use and responsibility will not be accepted for use in any other installation.
When first using the cooker ensure that the room is well ventilated (e.g. open
a window or use an extractor fan) and that persons who may be sensitive to
the odour avoid any fumes. It is suggested that any pets be removed from
the room until the smell has ceased. This odour is due to any temporary finish
and also any moisture absorbed by the insulation.
Our policy is one of continual improvement in design and development,
therefore strict accuracy of illustrations and descriptions cannot be guaranteed.
Installation
Prior to installation, ensure that the local distribution conditions (nature of the
gas and gas pressure) and the adjustment conditions are compatible. The
adjustment conditions for this appliance are stated on the data badge which
is fitted on the back panel.
This appliance is not designed to be connected to a combustion products
evacuation device. It must be installed and connected in accordance with
current installation regulations. particular attention should be given to the
relevant requirements regarding ventilation.
MODEL NUMBERS
CH10750GF S, CH10755GF S, CH10756GF S
Category I2H (GB)
This model is set to burn NATURAL GAS (G20) at 20 mbar
PLEASE PHONE US TO REGISTER YOUR APPLIANCE AND ACTIVATE YOUR PARTS GUARANTEE ON 08448 24 24 24
4
GAS SAFETY (INSTALLATION & USE) REGULATIONS
It is the law that all gas appliances are installed by competent persons in
accordance with the current edition of the above regulations. It is in your
interest and that of safety to ensure compliance with the law.
In the UK, CORGI registered installers work to safe standards of practice.
The cooker must also be installed in accordance with Current national
legislation.
Failure to install the cooker correctly could invalidate the warranty liability
claims and could lead to prosecution.
LOCATION
The cooker may be located in a kitchen, kitchen/diner or a bed-sitting room, but
not in a room containing a bath or shower. The cooker must not be installed
in a bed-sitting room of less than 20m
PROVISION FOR VENTILATION
The room containing the cooker should have an air supply in accordance with
Current national legislation.
The room must have an opening window or equivalent; some rooms may also
require a permanent vent. If the room has a volume between 5 and 10m
it will require an air vent of 50cm
effective area unless it has a door which
2
opens directly to outside. If the room has a volume of less than 5m
require an air vent of 100cm
effective area. If there are other fuel burning
2
appliances in the same room, in accordance with Current national legislation
should be consulted to determine air vent requirements.
TECHNICAL DATA (Main Left Oven and Main Right Oven)
Oven dimensions
37,0 x 38,0 x 44,8 cm
HxLxP
Volume
lt. 63
Voltage and
see data plate
frequency
may be adapted for use with any type
Burners
of gas shown on the data plate.
EU Directive no 65/2014
supplementing Directive 2010/30/EU.
EU Regulation no 66/2014
Energy
implementing Directive 2009/125/EC.
Label e
Standard EN 60350-1,
Ecodesign
Standard EN 30-2-1,
Standard EN 50564
This appliance conforms to the
following European Economic
Community directives:
- 2006/95/EC dated 12/12/06 (Low
Voltage) and subsequent amendments.
- 2004/108/EC dated 03/05/89
(Electromagnetic Compatibility) and
subsequent amendments.
- 93/68/EEC dated 22/07/93 and
subsequent amendments.
- 2009/142/EC dated 30/11/09 (Gas)
and subsequent amendments.
- 2012/19/EU and subsequent
amendments.
- 1275/2008 standby/off mode.
.
3
, it will
3
,
3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ch 10755 gf sCh 10756 gf s

Table of Contents